Introduction:
Numerous challenges remain in surgical training for endoscopic endonasal and transnasal procedures. Three-dimensional simulators are being developed to allow rapid and cost-effective acquisition of endoscopic surgical skills and anatomical knowledge. However, validation studies are limited.
Research Question:
This study aims to evaluate the role and effectiveness of the new UpSurgeOn TNSBox (transnasal transsphenoidal surgical simulator) in enhancing surgical skills compared to cadaveric dissection.
Material And Methods:
A total of 34 subjects, including neuro- and head and neck surgeons (both residents and junior consultants), were divided into two groups. Group 1 completed a dissection on a 3D simulator, followed by a cadaveric dissection, while Group 2 dissected only a cadaver. A training program covering several surgical steps was conducted and recorded. At the end of the course, each participant completed a structured questionnaire. Performance was evaluated by six blinded experts using the validated Endoscopic Surgery Rating Scale (G.R.S.). Performance scores were analyzed using Student's t-tests.
Results:
This study demonstrated that both specialists and residents beginning their training in endoscopic transsphenoidal surgery significantly improve their surgical skills when they undergo a simulation-based initial training program.
Discussion And Conclusion:
The new UpSurgeOn TNSBox can contribute to a hybrid training model that combines simulation with cadaveric dissection, enhancing the acquisition of basic endoscopic surgical skills.