Video Experimental Relacionado
Updated: Jan 13, 2026

Quantification of Levator Ani Hiatus Enlargement by Magnetic Resonance Imaging in Males and Females with Pelvic Organ Prolapse
Published on: April 17, 2019
Mejora de la Comprensión del Paciente sobre los Hallazgos de Resonancia Magnética de Fístula Perianal utilizando
Easan Anand1,2, Itai Ghersin1, Gita Lingam1,2
1Robin Phillips' Fistula Research Unit, St Mark's The National Bowel Hospital, London NW10 7NS, UK.
Abstract:
Background/Objectives: Large Language Models (LLMs) may help translate complex Magnetic Resonance Imaging (MRI) fistula reports into accessible, patient-friendly summaries. This study evaluated the clinical utility, safety, and patient acceptability of Generative Pre-trained Transformer (GPT-4o) in generating such reports. Methods: A three-phase study was conducted at a single centre. Phase I involved prompt engineering and pilot testing of GPT-4o outputs for feasibility. Phase II assessed 250 consecutive MRI fistula reports from September 2024 to November 2024, each reviewed by a multi-disciplinary panel to determine hallucinations and thematic content. Phase III randomised patients to review either a simple or complex fistula case, each containing an original report and an Artificial Intelligence (AI)-generated summary (order randomised, origin blinded), and rate readability, trustworthiness, usefulness and comprehension. Results: Sixteen patients participated in Phase I pilot testing. In Phase II, hallucinations occurred in 11% of outputs, with unverified recommendations also identified. In Phase III, 61 patients (mean age 48, 41% female) evaluated paired original and AI-generated summaries. AI summaries scored significantly higher for readability, comprehension, and usefulness than original reports (all p < 0.001), with equivalent trust ratings. Mean Flesch-Kincaid scores were markedly higher for AI-generated summaries (66 vs. 26; p < 0.001). Clinicians highlighted improved anatomical structuring and accessible language, but emphasised risks of inaccuracies. A revised template incorporating Multi-Disciplinary Team (MDT)-focused action points and a lay summary section was co-developed. Conclusions: LLMs can enhance the readability and patient understanding of complex MRI reports but remain limited by hallucinations and inconsistent terminology. Safe implementation requires structured oversight, domain-specific refinement, and clinician validation. Future development should prioritise standardised reporting templates incorporating clinician-approved lay summaries.
Videos de Conceptos Relacionados
Imaging Studies VI: Voiding Cystourethrography and Cystography
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...

