Protocol for the Evaluation of MRI Artifacts Caused by Metal Implants to Assess the Suitability of Implants and the Vulnerability of Pulse Sequences
Published on: May 17, 2018
Eficacia de la reducción de artefactos metálicos de energía única en angiotomografía computarizada para pacientes con
M Kara1, A Shatat1, M K Dönmez1
1Department of Radiology, Kocaeli University Medical Faculty, Izmit, Kocaeli, 41100, Turkey.
Aim:
To evaluate the impact of a single-energy metal artifact reduction algorithm on image quality in lower extremity CT angiography (CTA) of patients with metallic implants.
Materials And Methods:
This retrospective, single-center study included patients with metallic implants in the lower extremity who underwent lower extremity CTA between January 2021 and December 2024. All scans were performed on a 320-detector row CT scanner. Standard images were reconstructed with hybrid iterative reconstruction, and an additional reconstruction was performed with a projection-based single-energy metal artifact reduction (SEMAR) algorithm. Objective image quality was assessed by measuring image noise in target tissues (arteries, muscle, subcutaneous fat, cortical bone, medullary bone) on both standard and SEMAR images. Subjective image quality was evaluated for arteries, muscle, and bone using a 5-point scale. Scores ≥4 were considered diagnostic. Paired t-tests or Wilcoxon signed-rank tests were used for comparisons, as appropriate RESULTS: The study group included 30 patients. SEMAR reconstruction significantly reduced image noise and artifact index in all evaluated tissues compared to standard images with objective assessment (p<0.001 for each target tissue). Subjective evaluation of diagnostic-quality showed marked improvements with the SEMAR algorithm for each target tissue compared to the standard images using a 5-point scale (p<0.001 for each). For arterial structures, only 5 of 30 cases (16.6 %) were considered diagnostic on the standard images (score 4 or 5), whereas with SEMAR 28 of 30 cases (93.3 %) were diagnostic.
Conclusions:
SEMAR significantly reduced artifacts and image noise, restoring diagnostic image quality for vessels and surrounding tissues.
Más Videos Relacionados
07:48High Spatial Resolution Chemical Imaging of Implant-Associated Infections with X-ray Excited Luminescence Chemical Imaging Through Tissue
Published on: September 30, 2022
04:55Handheld Metal Detector Screening for Metallic Foreign Body Ingestion in Children
Published on: September 11, 2018
Videos de Conceptos Relacionados
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...