Video Experimental Relacionado
Updated: Jan 20, 2026

Diffusion Imaging in the Rat Cervical Spinal Cord
Published on: April 7, 2015
Modelos de Ondículas de Difusión de Eliminación de Ruido para Traducción de Imágenes Médicas sin Disparo
Yunxiang Li1, Xianghao Kong2, Jiacheng Xie1
1Medical Artificial Intelligence and Automation (MAIA) Laboratory, Department of Radiation Oncology, UT Southwestern Medical Center, Dallas, TX, 75390, USA.
Abstract:
Diffusion models excel in generating high-quality images, yet their application in medical image translation, specifically for cone-beam computed tomography (CBCT) to CT translation, often fails to accurately preserve intricate anatomical details. Conventional methods including GANs and VAEs also struggle with high-quality translation due to the challenges in learning bi-directional CBCT/CT distribution mapping and a lack of robustness to out-of-distribution (OOD) testing data. To address the challenges, we proposed a denoising diffusion wavelet model (DDWM), which only requires learning the CT data distribution in the training process and then performs zero-shot CBCT-to-CT translation through a similarity-bridge-controlled reverse diffusion process. In this process, domain-invariant information (e.g., anatomical structures in medical images) from the source image is fused into the result at each step of the reverse diffusion. Specifically, in our DDWM, we use wavelet transform to decompose the image into different frequency bands, then identify the bands where the source and target domains are most similar (i.e., the domain-invariant information). This information is incorporated into each step of the reverse process, preserving the anatomical structures of the original CBCT image and facilitating structure-faithful translation. Trained on a brain CT dataset (Dataset I) and evaluated on three CBCT-to-CT translation datasets (Datasets I-III) - with Datasets II&III being OOD - DDWM outperformed other state-of-the-art methods across all metrics, including Frechet Inception Distance (FID), Peak Signal-to-Noise Ratios (PSNR), Mean Absolute Error (MAE), and DICE scores, demonstrating superior image translation quality and anatomical fidelity.
Videos de Conceptos Relacionados
10:46Diffusion Imaging in the Rat Cervical Spinal Cord
08:21Wideband Optical Detector of Ultrasound for Medical Imaging Applications
10:33Advanced Diffusion Imaging in The Hippocampus of Rats with Mild Traumatic Brain Injury
Assessing Spinal Cord Compression Using Diffusion Tensor Imaging
07:00Diffusion Tensor Magnetic Resonance Imaging in Chronic Spinal Cord Compression
Diffusion

