Video Experimental Relacionado
Updated: Jan 23, 2026

Lower Limb Biomechanical Analysis of Healthy Participants
Published on: April 15, 2020
Establecimiento de valores de referencia en participantes sanos para el ensayo de alta sensibilidad de troponina T
Lori B Daniels1, Christian Mueller2, Evangelos Giannitsis3
1Division of Cardiovascular Medicine, Department of Medicine, University of California, San Diego, La Jolla, California, United States.
Background:
Measurement of cardiac troponin (cTn) using high-sensitivity assays is recommended for the diagnosis of myocardial infarction. We determined sex-specific and uniform 99th percentile upper reference limits (URLs) using the new Elecsys® Troponin T high-sensitivity Gen 6 assay in a global, healthy reference range cohort.
Methods:
Lithium-heparin (Li-Hep) plasma and serum samples were prospectively collected from apparently healthy individuals aged ≥20 years across 34 global sites in the United States, Europe, China, and Japan. cTnT was measured using the Troponin T high-sensitivity Gen 6 assay on the Cobas® e 801 analyzer. Exclusion criteria were defined according to the 2022 International Federation of Clinical Chemistry guidance. Uniform and sex-specific 99th percentile URLs and non-parametric 95% confidence intervals (CI) were determined in plasma and serum separately and combined.
Results:
The final study population comprised 4147 participants (52.5% female) with a median (25-75th percentiles) age of 48.0 (33.0-59.0) years; 45.8%, 47.9%, 5.2% and 1.1% were White, Asian, Black, and other/unknown, respectively. For sample matrices combined (n=8294), 81.0% and 99.2% of cTnT values were above the limit of detection in females and males, respectively. Sex-specific 99th percentile URLs (95% CI) were 18 (16-23) ng/L for females and 32 (28-35) ng/L for males; the uniform 99th percentile URL was 27 (24-31) ng/L. URLs were comparable in plasma and serum samples.
Conclusions:
This study determined sex-specific and uniform 99th percentile URLs for the Troponin T high-sensitivity Gen 6 assay that were comparable irrespective of the matrix used, in a large, global, healthy reference population.
Videos de Conceptos Relacionados
Inertial Frames of Reference
Non-inertial Frames of Reference
Chemical Shift: Internal References and Solvent Effects
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
Biodiversity and Human Values
Professional Values
The values that are the foundation of the nursing profession are altruism, autonomy, human dignity, and social justice.
First, altruism refers to the concern for the welfare and well-being of others without personal...
Critical Values

