Video Experimental Relacionado
Updated: Jan 23, 2026

Individualized Stem-positioning in Calcar-guided Short-stem Total Hip Arthroplasty
Published on: February 27, 2018
Resultados Funcionales a 10 Años Tras Artroplastia Total de Cadera Asistida por Robot: Una Serie de Casos
Benjamin G Domb1, Roger Quesada-Jimenez2, Shahar R Barda2
1American Hip Institute Research Foundation, Chicago, IL 60018; American Hip Institute, Chicago, IL 60018.
Background:
Robotic-assisted total hip arthroplasty (rTHA) has been shown to assist with precision in component placement. However, limited evidence exists evaluating its effects on minimum 10-year clinical outcomes. The purpose of this study was to report the minimum 10-year clinical outcomes in a case series of patients who underwent rTHA.
Methods:
Prospectively collected data from patients who underwent primary rTHA between June 2011 and April 2015 were analyzed. Patients who had a complete minimum 10-year follow-up, including radiographs and validated patient-reported outcomes (PROs), were included. A total of 215 hips met the inclusion criteria. The PROs included the Harris Hip Score (HHS), Hip Disability and Osteoarthritis Outcome Score-Joint Replacement (HOOS-JR), Forgotten Joint Score-12 (FJS-12), visual analog scale (VAS) pain, and patient satisfaction. Radiographic assessment included acetabular cup inclination, version, leg-length discrepancy, and cup placement relative to the Lewinnek and Callanan safe zones.
Results:
At final follow-up, patients reported excellent outcomes, with mean HHS 93.0 ± 12.6, HOOS-JR 89.1 ± 16.1, FJS-12 85.2 ± 22.4, VAS pain 1.0 ± 1.9, and satisfaction 9.1 ± 1.8. The high FJS-12 score reflects that patients rarely or almost never thought about their hip in daily life. There were six revisions (2.8%): one for aseptic loosening (0.5%), one for leg-length discrepancy (0.5%), and four for acute postoperative infection (1.9%). Survivorship free of revision was 97.2% at 10 years. Radiographic analysis demonstrated that 91.1% of cups were within the Lewinnek safe zone and 87.4% within the Callanan safe zone. Notably, there were no cases of instability or dislocation.
Conclusion:
Robotic-assisted primary THA was associated with a high degree of accuracy in component placement and durable clinical outcomes with high patient satisfaction and low revision rates at a minimum 10-year follow-up.
Videos de Conceptos Relacionados
Resistors In Series
In a series circuit, the...
Predicting Reaction Outcomes
Series Resonance
Outcomes of Glycolysis
Cellular respiration can occur aerobically (with oxygen) or anaerobically (without oxygen). In the presence of oxygen, cellular respiration starts with glycolysis and continues with pyruvate...
Trigonometric Fourier series
The trigonometric Fourier series specifically expresses a periodic function with a defined period T using sine...
Convergence of Fourier Series
The Gibbs phenomenon refers to the persistent oscillations and overshoots that occur near discontinuities...

