Video Experimental Relacionado
Updated: Jan 25, 2026

Fabricating Highly Open Porous Microspheres HOPMs via Microfluidic Technology
Published on: May 16, 2022
Sensor de fotopletismografía de alta sensibilidad habilitado por un OLED de micromalla altamente transparente
Dong Gyun Kim1, Minseong Park2, Young Woo Kim1
1Department of Semiconductor Engineering, Gachon University, Seongnam 13120, Republic of Korea.
Abstract:
Photoplethysmography (PPG) is a noninvasive technique for monitoring physiological signals, but conventional reflective configurations suffer from long and scattered reflection paths, leading to degraded signal quality. In this study, we propose a vertical reflective PPG structure using a transparent organic light-emitting diode (TOLED) with a mesh electrode, enabling reflected light to directly reach the photodiode (PD) through the mesh openings. The TOLED was fabricated by forming a Mg:Ag mesh cathode using a plus-shaped shadow mask, and at a pitch size of 1140 μm, the mesh electrode exhibited high optical transmittance (T550 > 80%) and low sheet resistance (≤12 Ω/□), while the overall device maintained good transparency (T550 = 71.5%). PPG measurements confirmed that the vertical structure enhanced signal collection efficiency, achieving the highest signal-to-noise ratio (SNR) of 35.18 dB at a pitch of 1140 μm. These results demonstrate the potential of mesh-based TOLEDs as a promising platform for next-generation wearable healthcare and transparent display applications.
Videos de Conceptos Relacionados
Administering Oxygen by Mask
Administering oxygen by mask is a common nursing intervention that provides supplemental oxygen to patients with respiratory distress or chronic lung conditions. This procedure involves delivering oxygen at a specified rate through a face mask connected to an oxygen source.
Equipment
The equipment necessary for this procedure includes:
Masking and Demasking Agents
There are many masking agents, such as cyanide, fluoride, triethanolamine, thiourea, and 2,3-bis(sulfanyl)propan-1-ol (formerly 2,3-dimercapto-1-propanol), with the masking agent chosen based on...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...
In-situ Hybridization
Types of probes and labels
A probe is a complementary strand of DNA or RNA that binds to corresponding nucleotide sequences in a cell. Many...