Efecto de los Modos de Presión de Impulso en las Características de Dispersión de Microchorros en Geles Simuladores
Dongping Zeng1,2, Longsheng Luo1, Linxing Luo1
1School of Energy and Power Engineering, Changsha University of Science and Technology, Changsha 410114, China.
Abstract:
Needle-free injection (NFI) technology is a promising alternative to conventional syringe injection, as it mitigates needle-related complications and enhances patient compliance. However, achieving the controlled and efficient dispersion of larger-volume formulations (>1 mL) within tissues remains a significant challenge. This study presents a novel pneumatic NFI system that uses a two-phase driving mode to regulate driving pressure and duration with an ejection volume of 1.0-2.0 mL. The integrated pressure stabilization unit significantly reduces pressure fluctuations during the initial injection phase, generating a more stable and uniform spray distribution. It is designed to produce an ideal elliptical dispersion effect while eliminating splatter, enabling controlled large-volume delivery. Jet impact experiments were conducted to investigate the dynamic characteristics of microjets generated by conventional single-phase and novel two-phase driving modes. Furthermore, the influence of the driving mode on the dispersion behaviors of microjets in agarose gels was explored through high-speed imaging of gel injections. The results demonstrate that the two-phase driving mode produces a distinct two-phase jet pressure profile. Compared to the single-phase mode, the two-phase mode produced a significantly larger dispersion width at equivalent initial driving pressures. This promotes more uniform lateral drug distribution and achieves a higher percentage of liquid drug delivery in gels. Furthermore, favorable driving pressure combinations were identified for different volumes: (1.25-0.25) MPa for 1.0 mL, (1.25-0.50) MPa for 1.5 mL, and (1.50-0.50) MPa for 2.0 mL. This provides a practical basis for optimizing clinical parameters and advancing the development of controllable NFI systems.
Videos de Conceptos Relacionados
Le Chatelier's Principle: Changing Volume (Pressure)
Pressure and Volume in an Adiabatic Process
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...
Distribution and Dispersion
Characteristics of Life
Vapor Pressure