Frequency Mixing Magnetic Detection Scanner for Imaging Magnetic Particles in Planar Samples
Published on: June 9, 2016
Efecto del volumen de referencia y de muestra en la cuantificación por imagen de partículas magnéticas
Sarah N Parrett1, Sebastian A Montero2, Hayden J Good2
1J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville FL 32601.
Abstract:
Magnetic particle imaging (MPI) is an emerging biomedical imaging modality that enables non-invasive quantification of superparamagnetic iron oxide nanoparticle (SPION) tracers by comparing signal in a region of interest (ROI) to that of reference samples of known tracer mass. However, despite growing interest and use of MPI, recent studies have raised concern over quantification accuracy as a function of the volume over which the tracer is distributed. Here, a constant mass dilution series of the tracer Ferucarbotran contained in well-defined sample geometries was used to evaluate the effect of relative reference and object sample volumes on MPI quantification accuracy. MPI images of this series were acquired under various scan modes, segmented using two commonly used methods, and iron mass quantified relative to two reference sample sets with different volumes. The maximum signal and percent error relative to ground truth were compared amongst these sample volumes, scan modes, analysis methods, and reference volumes. Tracer concentration influenced signal distribution and, in some cases, influenced iron estimation accuracy. Reference samples that were similar in volume to the volume of interest were found to provide the most accurate results across scan modes. The observed behavior is attributed to the partial volume effect, which arises due to the finite resolution in MPI. These results are discussed within the current scope of the field and suggest that care must be taken when selecting reference sample volume relative to test sample volume for quantitative MPI studies.
Más Videos Relacionados
08:40Absolute Quantification of Aβ1-42 in CSF Using a Mass Spectrometric Reference Measurement Procedure
Published on: March 21, 2017
11:32A Microfluidic Platform for Precision Small-volume Sample Processing and Its Use to Size Separate Biological Particles with an Acoustic Microdevice
Published on: November 23, 2015
Videos de Conceptos Relacionados
Motion Of A Charged Particle In A Magnetic Field
Subatomic Particles
Magnetic Resonance Imaging
Inertial Frames of Reference
Non-inertial Frames of Reference
Imaging Studies IV: Magnetic Resonance Imaging