Jove
Visualize
Contáctanos
JoVE
x logofacebook logolinkedin logoyoutube logo
ACERCA DE JoVE
Visión GeneralLiderazgoBlogCentro de Ayuda JoVE
AUTORES
Proceso de PublicaciónConsejo EditorialAlcance y PolíticasRevisión por ParesPreguntas FrecuentesEnviar
BIBLIOTECARIOS
TestimoniosSuscripcionesAccesoRecursosConsejo Asesor de BibliotecasPreguntas Frecuentes
INVESTIGACIÓN
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchivo
EDUCACIÓN
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualCentro de Recursos para ProfesoresSitio de Profesores
Términos y Condiciones de Uso
Política de Privacidad
Políticas

Videos de Conceptos Relacionados

Electrodeposition01:08

Electrodeposition

1.5K
Electrodeposition is a technique used to separate an analyte from interferents by electrochemical processes. Here, the analyte is a metal ion that can be deposited on an electrode immersed in the sample solution. The electrochemical setup consists of an anode and a cathode. When an electric current is applied to the setup, oxidation occurs at the anode. At the cathode, which consists of a large metal surface, metal ions undergo reduction and deposit onto the surface.
Electrodeposition can...
1.5K
Microbial Morphologies01:29

Microbial Morphologies

2.5K
Bacterial and archaeal cells exhibit remarkable diversity in shape and structure, critical in their adaptability and functionality. Among bacteria, the most commonly observed shapes include cocci and bacilli. Cocci are spherical and may exist singly or in groupings such as pairs (diplococci), chains (streptococci), clusters (staphylococci), or tetrads. Bacilli, in contrast, are rod-shaped and can also occur as single cells, in pairs, or chains, depending on their environmental and genetic...
2.5K
Uncertainty in Measurement: Reading Instruments02:46

Uncertainty in Measurement: Reading Instruments

51.7K
Counting is the type of measurement that is free from uncertainty, provided the number of objects being counted does not change during the process. Such measurements result in exact numbers. By counting the eggs in a carton, for instance, one can determine exactly how many eggs are there in the carton. Similarly, the numbers of defined quantities are also exact. For example, 1 foot is exactly 12 inches, 1 inch is exactly 2.54 centimeters, and 1 gram is exactly 0.001 kilograms. Quantities...
51.7K
Surface Tension, Capillary Action, and Viscosity02:57

Surface Tension, Capillary Action, and Viscosity

33.3K
Surface Tension
The various IMFs between identical molecules of a substance are examples of cohesive forces. The molecules within a liquid are surrounded by other molecules and are attracted equally in all directions by the cohesive forces within the liquid. However, the molecules on the surface of a liquid are attracted only by about one-half as many molecules. Because of the unbalanced molecular attractions on the surface molecules, liquids contract to form a shape that minimizes the number...
33.3K
Antiepileptic Drugs: Modulators of Neurotransmitter Release Mediated by SV2A Protein01:20

Antiepileptic Drugs: Modulators of Neurotransmitter Release Mediated by SV2A Protein

904
Antiepileptic drugs, such as levetiracetam (Keppra) and brivaracetam (Briviact), have emerged as crucial tools in managing epilepsy. These medications exert their therapeutic effects by targeting the synaptic vesicle protein SV2A, a transmembrane glycoprotein primarily found in the brain.
SV2A is a transmembrane glycoprotein located predominantly in the brain, modulating the release of neurotransmitters for neuronal communication. Both levetiracetam and brivaracetam exhibit a high affinity for...
904
Adhesion01:14

Adhesion

44.3K
Adhesion occurs when one type of molecule is attracted to a different molecule. Water exhibits adhesive properties in the presence of polar surfaces, such as glass or cellulose in plants. For instance, when water is poured into a glass, the positively charged hydrogen molecules of water are more attracted to the negatively charged oxygen molecules in the silica than to the oxygen in neighboring water molecules.
Capillary action is a result of water’s adhesive tendencies. When a narrow...
44.3K

También podría leer

Artículos Relacionados

Artículos vinculados a este trabajo por autores compartidos, revista y gráfico de citas.

Ordenar por
Same author

Maternal Cardiac Disease and Congenital Heart Disease Risk in Offspring.

JAMA network open·2026
Same author

BMPR2 affects valve development via ECM-receptor interaction in zebrafish.

Frontiers in cell and developmental biology·2026
Same author

Employment of the Ascending Aortic Volume as a Predictor of Adverse Outcomes in Patients With Bicuspid Aortic Valve Disease.

Reviews in cardiovascular medicine·2026
Same author

Reply to the Letter to the Editor "Sex imbalance in a large Fontan cohort: Biological reality or marker of inequitable care?"

Revista portuguesa de cardiologia : orgao oficial da Sociedade Portuguesa de Cardiologia = Portuguese journal of cardiology : an official journal of the Portuguese Society of Cardiology·2026
Same author

Widening effect of SICM topography measurement based on electrolyte concentration gradient with dual-barrel pipette.

Micron (Oxford, England : 1993)·2026
Same author

Ameliorating post-infarction myocardial fibrosis and cardiac function via ROS-responsive hydrogel-mediated IL-11 antibody delivery.

Bioactive materials·2026

Video Experimental Relacionado

Updated: Jan 31, 2026

Destabilization of the Medial Meniscus and Cartilage Scratch Murine Model of Accelerated Osteoarthritis
07:06

Destabilization of the Medial Meniscus and Cartilage Scratch Murine Model of Accelerated Osteoarthritis

Published on: July 6, 2022

5.8K

Un método de modulación de la morfología del menisco para la electrodeposición confinada por menisco

Yi Zhou1, Xiaobo Liao1, Long Chen1

  • 1Key Laboratory of Testing Technology for Manufacturing Process, Ministry of Education, Southwest University of Science and Technology, Manyang 621010, China. liaoxiaobo@swust.edu.cn.

Nanoscale
|January 30, 2026
PubMed
Resumen

Los investigadores desarrollaron un nuevo método para controlar la morfología del menisco en la electrodeposición confinada por menisco (MCED) ajustando la presión. Esto mejora la estabilidad de la deposición y permite la fabricación de microestructuras 3D complejas.

Palabras clave:
electrodeposición confinada por meniscomicrofabricaciónmorfología del meniscocontrol de presiónestructuras 3D

Más Videos Relacionados

Physiological, Morphological and Neurochemical Characterization of Neurons Modulated by Movement
07:04

Physiological, Morphological and Neurochemical Characterization of Neurons Modulated by Movement

Published on: April 21, 2011

14.2K
Differential Effects of Lipid-lowering Drugs in Modulating Morphology of Cholesterol Particles
09:15

Differential Effects of Lipid-lowering Drugs in Modulating Morphology of Cholesterol Particles

Published on: November 10, 2017

15.1K

Videos de Experimentos Relacionados

Last Updated: Jan 31, 2026

Destabilization of the Medial Meniscus and Cartilage Scratch Murine Model of Accelerated Osteoarthritis
07:06

Destabilization of the Medial Meniscus and Cartilage Scratch Murine Model of Accelerated Osteoarthritis

Published on: July 6, 2022

5.8K
Physiological, Morphological and Neurochemical Characterization of Neurons Modulated by Movement
07:04

Physiological, Morphological and Neurochemical Characterization of Neurons Modulated by Movement

Published on: April 21, 2011

14.2K
Differential Effects of Lipid-lowering Drugs in Modulating Morphology of Cholesterol Particles
09:15

Differential Effects of Lipid-lowering Drugs in Modulating Morphology of Cholesterol Particles

Published on: November 10, 2017

15.1K

Área de la Ciencia:

  • Ciencia de los materiales
  • Microfabricación
  • Electroquímica

Sus antecedentes:

  • La electrodeposición confinada por menisco (MCED) es una técnica prometedora de micro y nano fabricacion.
  • MCED ofrece bajo costo, procesamiento simple y la capacidad de crear estructuras 3D complejas.
  • Sin embargo, la continuidad y estabilidad de la deposición de MCED se ven obstaculizadas por factores externos que afectan la morfología del menisco.

Objetivo del estudio:

  • Desarrollar un método novedoso para regular la morfología del menisco en MCED.
  • Mejorar la estabilidad y continuidad del proceso de electrodeposición.
  • Ampliar las capacidades de fabricación de microestructuras 3D complejas.

Principales métodos:

  • Se desarrolló un método de regulación de la morfología del menisco utilizando presurización de extremo de cola de sondas de vidrio.
  • Se controló la presión interna de la solución para ajustar el radio del perfil del menisco.
  • Se realizaron simulaciones y experimentos para validar el método.

Principales resultados:

  • El ajuste de la presión de la solución (-5 kPa a 5 kPa) controló el ancho del menisco de 0,6 a 1,5 veces el valor inicial.
  • Se fabricó con éxito un conjunto de pilares de cobre (altura de 33 μm, ancho de 7-15 μm) controlando el diámetro del menisco.
  • Se demostró una mejora en la continuidad y estabilidad de la deposición electroquímica.

Conclusiones:

  • El método desarrollado de control de presión regula eficazmente la morfología del menisco en MCED.
  • Esta técnica mejora la estabilidad de la deposición y permite la preparación de microestructuras 3D complejas.
  • Los hallazgos amplían el alcance de aplicación de la electrodeposición confinada por menisco.