Objectives:
Conventional annuloplasty rings used in mitral valve repair (MVr) are made of metal or synthetic polymers, which may increase infection risk. This study aimed to develop a mitral annuloplasty ring using decellularised tissue and evaluate its ability to suppress regurgitation in a degenerative mitral regurgitation (DMR) model.
Methods:
A 4 mm diameter annuloplasty ring was created using decellularized bovine tendon. Porcine mitral valve complexes (including the annulus, leaflets, chordae tendineae, and papillary muscles) were obtained from a slaughterhouse. The annulus was enlarged by 4 mm, and the two chordae tendineae of the posterior leaflet (P2) were severed. The DMR model, integrated into a pulsatile flow simulator, was repaired using a commercial-Physio II, Colvin-Galloway (CG) Future, Tailor band, and a decellularised tendon-based ring. Regurgitation control and effective mitral valve area (MVA) were compared (n = 6 for each group).
Results:
The regurgitation rate of the DMR model was 52.3 ± 3.4%, consistent with severe MR. Post-MVr with each ring, the regurgitation rates were 14.9 ± 3.1% (Physio II), 14.5 ± 1.1% (CG Future), 16.4 ± 1.7% (Tailor band), and 15.5 ± 3.0% (decellularised tendon-based biological ring). All of these rates were significantly reduced, with no significant differences among them. Effective MVA was comparable across groups: 2.46 ± 0.28 cm2 (Physio II), 2.33 ± 0.54 cm2 (CG Future), 2.28 ± 0.12 cm2 (Tailor band), and 2.27 ± 0.53 cm2 (decellularised tendon-based biological ring).
Conclusions:
The decellularised tendon-based annuloplasty ring demonstrated functional performance comparable to that of current mitral annuloplasty devices.
Más Videos Relacionados
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
11:16In vitro Assessment of Aortic Regurgitation Using Four-Dimensional Flow Magnetic Resonance Imaging
Published on: February 25, 2022
Videos de Conceptos Relacionados
Mitral Regurgitation I: Introduction
Mitral Regurgitation III: Medical Management
Mitral Regurgitation IV: Nursing Management
Mitral Regurgitation II: Clinical Features and Diagnostic Tests
Aortic Regurgitation I: Introduction
Mitral Stenosis I: Introduction