Video Experimental Relacionado
Updated: Feb 10, 2026

Characterizing Far-infrared Laser Emissions and the Measurement of Their Frequencies
Published on: December 18, 2015
Áreas de Alta Frecuencia como Pista Elect Fisiológica para la Ablación de Vías Accesorias: Caracterización de la
Takashige Sakio1, Takashi Kanda2, Hitoshi Minamiguchi2
1Cardiovascular Division, Osaka Keisatsu Hospital, Osaka, Japan.
Background:
Catheter ablation (CA) is a curative therapy for atrioventricular reentrant tachycardia (AVRT) caused by accessory pathways (APs), but precise AP localization with conventional mapping can be challenging. While omnipolar technology near-field (OTNF) provides novel frequency-based analysis, its clinical utility for AP ablation remains unproven.
Objective:
We aimed to characterize the spatial relationship between high-frequency areas identified by OTNF-derived peak frequency maps and successful AP ablation sites.
Methods:
This multicenter retrospective study analyzed OTNF data from 33 patients undergoing successful CA for AVRT. Offline peak frequency analysis was performed on acquired open-window mapping data. We measured: (1) the peak frequency (PF) at the successful ablation site, (2) the highest PF in the immediate vicinity, (3) the spatial distance, and (4) the directional displacement between these two points.
Results:
While successful ablation sites were located in areas of high frequency (mean 332 ± 206 Hz), the absolute highest PF was consistently found in the immediate vicinity (mean 435 ± 56 Hz; p < 0.01). Critically, the site of the highest PF was spatially displaced from the successful ablation site by a median distance of 4 mm (IQR: 0-6 mm). Directionally, when viewed from the annulus, the highest frequency site was co-located with the successful site in 21 cases (64%), shifted counter-clockwise in 9 cases (27%), and clockwise in 3 cases (9%).
Conclusion:
High-frequency areas on OTNF maps are consistently located adjacent to, but spatially distinct from, successful AP ablation sites. This quantifiable spatial dissociation represents a novel electrophysiological target that may improve the precision and efficiency of AP catheter ablation.
Más Videos Relacionados
09:13Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures
Published on: April 21, 2013
07:04A Novel Use of Three-dimensional High-frequency Ultrasonography for Early Pregnancy Characterization in the Mouse
Published on: October 24, 2017
Videos de Conceptos Relacionados
Frequency-dependent Selection
What is a Frequency Distribution
Mean From a Frequency Distribution
When such a data set is encountered,...
Muscle Stimulation Frequency
Wave summation
At low firing rates, motor neurons induce individual twitch contractions in muscle fibers. These twitches...
Frequency Response of BJT
Low-Frequency Response: At low frequencies, the behavior of the BJT is determined by its DC bias point, which is set by the...
Load-frequency control