Jove
Visualize
Contáctanos

Videos de Conceptos Relacionados

Magnetic Resonance Imaging01:24

Magnetic Resonance Imaging

9.9K
Magnetic resonance imaging (MRI) is a noninvasive medical imaging technique based on a phenomenon of nuclear physics discovered in the 1930s, in which matter exposed to magnetic fields and radio waves was found to emit radio signals. In 1970, a physician and researcher named Raymond Damadian noticed that malignant (cancerous) tissue gave off different signals than normal body tissue. He applied for a patent for the first MRI scanning device in clinical use by the early 1980s. The early MRI...
9.9K
Imaging Studies IV: Magnetic Resonance Imaging01:27

Imaging Studies IV: Magnetic Resonance Imaging

296
Introduction:Magnetic Resonance Imaging, or MRI, can include a specialized imaging technique of the urinary system known as Magnetic Resonance Urography (MRU). This radiation-free technique uses strong magnetic fields and radio waves to produce detailed images with the help of a computer. MRU is particularly effective for visualizing fluid-filled structures like the kidneys, ureters, and bladder.Applications of MRI in the Genitourinary SystemKidneys and Ureters: MRI detects tumors, cysts,...
296
Imaging Studies for Cardiovascular System IV: CMRI01:21

Imaging Studies for Cardiovascular System IV: CMRI

420
Cardiovascular magnetic resonance imaging, or CMRI, is a non-invasive diagnostic test that employs a magnetic field and radiofrequency waves to create precise images of the heart and arteries. It provides comprehensive information about cardiac anatomy, function, perfusion, and tissue characterization without ionizing radiation.IndicationsCMRI diagnoses various heart conditions, including tissue damage from heart attacks, ischemic heart disease, myocarditis, aortic issues (tears, aneurysms,...
420

También podría leer

Artículos Relacionados

Artículos vinculados a este trabajo por autores compartidos, revista y gráfico de citas.

Ordenar por
Same author

Tongue volume in spinal and bulbar muscular atrophy (SBMA): an AI-assisted automatic MRI analysis.

Journal of neurology·2026
Same author

Correction: Design and chemical composition of a reference phantom for <sup>13</sup>C metabolic MRSI.

Magma (New York, N.Y.)·2026
Same author

Detection of inflammation-related blood-brain barrier dysfunction using PET and MR imaging: a pilot study.

Scientific reports·2026
Same author

NF-κB activation in astrocytes impairs wound healing after traumatic brain injury in male mice.

Nature communications·2026
Same author

Design and chemical composition of a reference phantom for <sup>13</sup>C metabolic MRSI.

Magma (New York, N.Y.)·2026
Same author

[Relevance of Adapted Dynamic MRI Protocols in the Diagnosis of Articular Disc Displacements].

RoFo : Fortschritte auf dem Gebiete der Rontgenstrahlen und der Nuklearmedizin·2026
Same journal

Determination of long-range resistance from high resolution impedance spectroscopy in human cadaveric heads.

Zeitschrift fur medizinische Physik·2026
Same journal

Patient-specific quality assurance in stereotactic radiotherapy: clinical practice in absence of guidelines - status and new approach from the DGMP working group for physics and technology in stereotactic radiotherapy.

Zeitschrift fur medizinische Physik·2026
Same journal

Potential and challenges of Positron Emission Tomography beyond conventional preclinical and clinical imaging.

Zeitschrift fur medizinische Physik·2026
Same journal

Evaluation of PET/CT Artificial Intelligence Image Reconstructions VS Harmonized Clinical Reconstruction.

Zeitschrift fur medizinische Physik·2026
Same journal

Adaptation of quality control pipeline for Skeletal Muscle 31P MR Spectroscopy at 3T and 7T.

Zeitschrift fur medizinische Physik·2026
Same journal

Complexity metrics for Tomotherapy: application to the verification of transferred plans.

Zeitschrift fur medizinische Physik·2026
Ver todos los artículos relacionados
JoVE
x logofacebook logolinkedin logoyoutube logo
ACERCA DE JoVE
Visión GeneralLiderazgoBlogCentro de Ayuda JoVE
AUTORES
Proceso de PublicaciónConsejo EditorialAlcance y PolíticasRevisión por ParesPreguntas FrecuentesEnviar
BIBLIOTECARIOS
TestimoniosSuscripcionesAccesoRecursosConsejo Asesor de BibliotecasPreguntas Frecuentes
INVESTIGACIÓN
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchivo
EDUCACIÓN
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualCentro de Recursos para ProfesoresSitio de Profesores
Términos y Condiciones de Uso
Política de Privacidad
Políticas

Video Experimental Relacionado

Updated: Feb 17, 2026

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
08:51

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla

Published on: February 19, 2021

9.9K

Marco de simulación y reconstrucción de RM para campos vectoriales de magnetización/recepción y codificación de

Fabian Bschorr1, Thomas Hüfken1, Tobias Lobmeyer1

  • 1Ulm University Medical Center, Albert-Einstein-Allee 23, Ulm, 89081, Baden-Württemberg, Germany.

Zeitschrift fur medizinische Physik
|February 15, 2026
PubMed
Resumen
Este resumen es generado por máquina.

Un nuevo marco de simulación de MATLAB maneja campos magnéticos complejos en RM, mejorando la calidad de imagen para sistemas portátiles. Esta herramienta ayuda en el diseño de nuevos escáneres y el desarrollo de métodos de corrección de artefactos.

Palabras clave:
simulación de Blochcampos magnéticos desviadosRM de bajo camposimulación de RMcódigo abierto

Más Videos Relacionados

Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging
10:44

Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging

Published on: June 21, 2024

1.2K
High-resolution Functional Magnetic Resonance Imaging Methods for Human Midbrain
10:06

High-resolution Functional Magnetic Resonance Imaging Methods for Human Midbrain

Published on: May 10, 2012

13.5K

Videos de Experimentos Relacionados

Last Updated: Feb 17, 2026

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla
08:51

Magnetic Resonance Imaging of Multiple Sclerosis at 7.0 Tesla

Published on: February 19, 2021

9.9K
Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging
10:44

Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging

Published on: June 21, 2024

1.2K
High-resolution Functional Magnetic Resonance Imaging Methods for Human Midbrain
10:06

High-resolution Functional Magnetic Resonance Imaging Methods for Human Midbrain

Published on: May 10, 2012

13.5K

Área de la Ciencia:

  • Resonancia Magnética (RM)
  • Tecnología de Imagen Médica
  • Física Computacional

Sus antecedentes:

  • La RM convencional asume campos magnéticos homogéneos, lo que se ve desafiado por sistemas portátiles y de bajo costo.
  • Los campos magnéticos no ideales en el nuevo hardware de RM pueden causar artefactos, lo que afecta la calidad de la imagen.
  • Las herramientas de simulación son cruciales para diseñar nuevos sistemas de RM y optimizar las secuencias de imagen.

Objetivo del estudio:

  • Desarrollar un marco de simulación versátil basado en MATLAB para sistemas de RM con campos magnéticos no ideales.
  • Generalizar y validar simulaciones de Bloch basadas en matrices para una computación más rápida.
  • Evaluar la calidad de imagen y las estrategias de compensación de artefactos en entornos de campo magnético no ideal.

Principales métodos:

  • Se desarrolló un marco de MATLAB para simular vectores completos de campo magnético (B0, SEM, campos de transmisión/recepción).
  • Se generalizó y validó la simulación de Bloch basada en matrices para mayor eficiencia.
  • Se predijo la calidad de la imagen en experimentos de eco de gradiente 2D con campos magnéticos desviados.

Principales resultados:

  • La simulación generalizada basada en matrices mostró una reducción sustancial del tiempo en comparación con los métodos convencionales.
  • Las imágenes simuladas y reconstruidas coincidieron estrechamente entre los enfoques numéricos de Bloch y basados en matrices.
  • Se demostró la compensación de artefactos integrando el conocimiento del campo magnético en el proceso de reconstrucción.

Conclusiones:

  • El software validado permite la simulación y reconstrucción integral considerando configuraciones arbitrarias de campo magnético.
  • Esta herramienta es valiosa para diseñar nuevos sistemas de RM de bajo campo y desarrollar algoritmos de reconstrucción avanzados.
  • El marco facilita la interpretación de artefactos y la optimización de secuencias de imagen para hardware de RM no ideal.