Video Experimental Relacionado
Updated: Feb 17, 2026

Author Spotlight: Self-Assessment Protocol for Predicting Psoriatic Arthritis in Psoriasis Patients
Published on: March 1, 2024
Propiedades de medición de la Puntuación de Actividad de la Polimialgia Reumática (PMR-AS): fiabilidad, error de
Noortje E S E P Kooijman1,2, David F Ten Cate1, Pauline M E T Bovens1
1Department of Rheumatology, Sint Maartenskliniek, Nijmegen, the Netherlands.
Objectives:
The Polymyalgia Rheumatica Activity Score (PMR-AS) is the best validated composite disease activity measure in PMR to date, but its reliability, measurement error and discriminative validity have not been studied.
Methods:
Inter-rater reliability, measurement error and discriminative validity were assessed in a cross-sectional cohort of PMR patients in routine care (April-August 2025). For inter-rater reliability and measurement error, five physicians scored the PMR-AS, with two independently evaluating each patient at the same visit. Test-retest reliability and measurement error were assessed using data from two randomized trials in newly diagnosed PMR (2019-2024, EULAR/ACR criteria positive). Patients with two visits 2-4 weeks apart and no reported change in disease state were included. Analyses included intraclass correlation coefficients (ICC), standard error of measurement (SEM), smallest detectable change (SDC/SDD) and ROC analyses. Agreement between disease activity categories (PMR-AS <10 and ≥10) was evaluated using Cohen's kappa (ᴋ).
Results:
A total of 124 patients contributed to the inter-rater analyses and 38 for test-retest analyses. For inter-rater reliability, the PMR-AS showed excellent agreement (ICC 0.93, 95% CI 0.90-0.95). Test-retest reliability was lower (ICC 0.66, 95% CI 0.38-0.82), reflecting lack of variability in disease activity (median PMR-AS 1.6). Measurement error was notable (inter-rater: SEM 2.46, SDD 6.83; test-retest: SEM 2.07, SDC 5.75), but discriminative validity was good (AUC 0.93, ᴋ 0.69).
Conclusion:
The PMR-AS demonstrated excellent inter-rater reliability and discriminative validity, supporting its use for classification of disease activity. However, its measurement error may limit interpretation of small intra-individual changes.
Más Videos Relacionados
08:40Isokinetic Robotic Device to Improve Test-Retest and Inter-Rater Reliability for Stretch Reflex Measurements in Stroke Patients with Spasticity
Published on: June 12, 2019
10:58Multimedia Battery for Assessment of Cognitive and Basic Skills in Mathematics BM-PROMA
Published on: August 28, 2021