Jove
Visualize
Contáctanos
JoVE
x logofacebook logolinkedin logoyoutube logo
ACERCA DE JoVE
Visión GeneralLiderazgoBlogCentro de Ayuda JoVE
AUTORES
Proceso de PublicaciónConsejo EditorialAlcance y PolíticasRevisión por ParesPreguntas FrecuentesEnviar
BIBLIOTECARIOS
TestimoniosSuscripcionesAccesoRecursosConsejo Asesor de BibliotecasPreguntas Frecuentes
INVESTIGACIÓN
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchivo
EDUCACIÓN
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualCentro de Recursos para ProfesoresSitio de Profesores
Términos y Condiciones de Uso
Política de Privacidad
Políticas

Videos de Conceptos Relacionados

Computed Tomography01:10

Computed Tomography

9.0K
Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
9.0K

También podría leer

Artículos Relacionados

Artículos vinculados a este trabajo por autores compartidos, revista y gráfico de citas.

Ordenar por
Same author

Incidence of Adverse Cardiac Events After Liver Transplantation in Patients With Different Hemodynamic Classifications of Pulmonary Hypertension.

International journal of hepatology·2026
Same author

Super-resolution deep learning reconstruction improves the depiction of peripancreatic arteries and image quality in pancreatic cancer CT.

Abdominal radiology (New York)·2026
Same author

Convexal subarachnoid hemorrhage due to infective endocarditis: a rare forensic autopsy case.

Journal of forensic and legal medicine·2026
Same author

Peritoneal Dissemination after Preoperative Percutaneous Transhepatic Portal Vein Embolization in Hilar Cholangiocarcinoma: A Rare but Serious Complication.

Interventional radiology (Higashimatsuyama-shi (Japan)·2026
Same author

Evaluation of super-resolution deep learning reconstruction on three-dimensional constructive interference in steady state for enhanced visualization of vestibular schwannomas.

Radiological physics and technology·2026
Same author

Comparison of Postoperative MELD-Based Scores in Predicting Mortality After Liver Transplantation: A Retrospective Comparative Study.

International journal of hepatology·2026

Video Experimental Relacionado

Updated: Feb 17, 2026

High Resolution 3D Imaging of the Human Pancreas Neuro-insular Network
09:54

High Resolution 3D Imaging of the Human Pancreas Neuro-insular Network

Published on: January 29, 2018

11.6K

Cambios Postmortem Tempranos en el Páncreas: Un Estudio de Tomografía Computarizada Antemortem y Postmortem

Terumi Umeda1, Shohei Inui2, Satori Gonoi3

  • 1Radiology, Shimane University, Izumo, JPN.

Cureus
|February 16, 2026
PubMed
Resumen

Las imágenes postmortem tempranas muestran una disminución significativa en la densidad y el volumen pancreáticos saludables. Estos hallazgos son cruciales para interpretar las tomografías computarizadas postmortem (TCPM) del páncreas.

Palabras clave:
tomografía computarizadaradiología forensepáncreastomografía computarizada postmortemimágenes postmortem

Más Videos Relacionados

Dissection of the Mouse Pancreas for Histological Analysis and Metabolic Profiling
08:21

Dissection of the Mouse Pancreas for Histological Analysis and Metabolic Profiling

Published on: August 19, 2017

40.0K
Stabilized Longitudinal In Vivo Cellular-Level Visualization of the Pancreas in a Murine Model with a Pancreatic Intravital Imaging Window
06:52

Stabilized Longitudinal In Vivo Cellular-Level Visualization of the Pancreas in a Murine Model with a Pancreatic Intravital Imaging Window

Published on: May 6, 2021

4.8K

Videos de Experimentos Relacionados

Last Updated: Feb 17, 2026

High Resolution 3D Imaging of the Human Pancreas Neuro-insular Network
09:54

High Resolution 3D Imaging of the Human Pancreas Neuro-insular Network

Published on: January 29, 2018

11.6K
Dissection of the Mouse Pancreas for Histological Analysis and Metabolic Profiling
08:21

Dissection of the Mouse Pancreas for Histological Analysis and Metabolic Profiling

Published on: August 19, 2017

40.0K
Stabilized Longitudinal In Vivo Cellular-Level Visualization of the Pancreas in a Murine Model with a Pancreatic Intravital Imaging Window
06:52

Stabilized Longitudinal In Vivo Cellular-Level Visualization of the Pancreas in a Murine Model with a Pancreatic Intravital Imaging Window

Published on: May 6, 2021

4.8K

Área de la Ciencia:

  • Radiología forense; Imagenología médica; Imagenología pancreática

Sus antecedentes:

  • La investigación de los cambios postmortem tempranos en el páncreas es esencial para la interpretación precisa de los hallazgos de imagen.; El análisis longitudinal a través de la tomografía computarizada antemortem (AMCT) y la tomografía computarizada postmortem (PMCT) proporciona información valiosa sobre estos cambios.

Objetivo del estudio:

  • Investigar longitudinalmente los cambios postmortem tempranos en el páncreas saludable utilizando tomografía computarizada (TC).; Cuantificar los cambios en el volumen y la densidad pancreáticos desde las imágenes antemortem hasta las postmortem.

Principales métodos:

  • Se incluyeron pacientes adultos con páncreas sanos confirmados por autopsia.; Se analizaron TC de AMCT y PMCT sin contraste.; Se midieron y compararon estadísticamente el volumen, la densidad y los parámetros de la distribución de frecuencias (asimetría, curtosis) pancreáticos.

Principales resultados:

  • Se observó una disminución significativa en la densidad pancreática (AMCT: 31,2 HU frente a PMCT: 26,6 HU).; El volumen pancreático también se redujo significativamente (AMCT: 63,8 ml frente a PMCT: 56,8 ml).; La asimetría de la distribución de frecuencias de la densidad pancreática aumentó significativamente postmortem, mientras que la curtosis no mostró diferencias significativas.

Conclusiones:

  • La densidad y el volumen del páncreas sano disminuyen significativamente en el período postmortem temprano.; Estos cambios cuantitativos proporcionan una línea de base para interpretar las imágenes pancreáticas postmortem normales.; Los hallazgos ayudan a diferenciar los cambios postmortem de las condiciones patológicas en radiología forense y clínica.