Measurement of X-ray Beam Coherence along Multiple Directions Using 2-D Checkerboard Phase Grating
Published on: October 11, 2016
Evaluación de la coherencia y primera demostración de tomografía computarizada de rayos X multiconstraste en
Ryosuke Ueda1, Xiaoyu Liang2, Chika Kamezawa2
1International Center for Synchrotron Radiation Innovation Smart (SRIS), Tohoku University, Katahira 2-1-1, Aoba-ku, Sendai 980-8577, Japan.
La línea de haz BL09W en NanoTerasu demuestra alta coherencia espacial, lo que permite imágenes avanzadas de rayos X multiconstraste. Esta fuente de rayos X versátil es adecuada para diversas aplicaciones de imágenes basadas en coherencia.
Conclusiones:
- La línea de haz BL09W posee alta coherencia espacial, cumpliendo las expectativas de diseño.
- La línea de haz se valida como una plataforma versátil para técnicas avanzadas de imágenes de rayos X basadas en coherencia.
- La línea de haz BL09W de NanoTerasu es muy adecuada para aplicaciones que requieren imágenes de rayos X multiconstraste de alta resolución.
Más Videos Relacionados
Videos de Conceptos Relacionados
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
X-ray Imaging
Electron Microscope Tomography and Single-particle Reconstruction
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Imaging Studies III: Computed Tomography
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...