Video Experimental Relacionado
Updated: May 5, 2026

Video-rate Scanning Confocal Microscopy and Microendoscopy
Published on: October 20, 2011
Un diagnóstico flexible de tramado multifibra para imágenes de plasmas de potencia pulsada de múltiples GHz
Raimi Clark1, Matthew Burnette2, Karin Fulford2
1Texas Tech University, Lubbock, Texas 79409, USA.
Abstract:
A platform for multi-GHz frame rate imaging using a single intensified gating camera that relies on staggered optical delays in high-resolution optical fibers is introduced. The diagnostic consists of a beam splitter assembly that partitions the image, varying-length high-resolution optical fibers that stagger the image in time, and a gated camera that simultaneously images the fiber outputs. The time delay of the fibers is calibrated using a laser pulser and a fast photodiode. Individual channels are rotated due to the orientation of their respective fibers and may be flipped in the beam splitter assembly, so a simple post-processing technique is used to extract the frames. An eight-channel, 4 GHz frame rate version of this diagnostic was constructed using an intensified charge-coupled device (ICCD) with 3 ns gate times and was fielded to image visible light emission from a developing high voltage vacuum flashover event. Potential improvements or variations in this diagnostic to achieve a range of imaging capabilities for pulsed power plasmas are discussed.