Jove
Visualize
Contáctanos

Videos de Conceptos Relacionados

Fast Reactions01:27

Fast Reactions

Fast reactions occurring in times shorter than the time needed to mix reactants pose a unique challenge for investigation. In a liquid-phase continuous-flow system, reactants A and B are swiftly pushed into the mixing chamber, where mixing occurs within 1 ms. The reaction mixture then flows through an observation tube, and one measures light absorption to determine species concentrations at various points of the tube. This method is most appropriate when relatively large volumes of reactants...

También podría leer

Artículos Relacionados

Artículos vinculados a este trabajo por autores compartidos, revista y gráfico de citas.

Ordenar por
Same author

A light-initiated chemical reporter strategy for spatiotemporal labeling of biomolecules.

RSC chemical biology·2022
Same author

Downregulation of HULC Induces Ferroptosis in Hepatocellular Carcinoma via Targeting of the miR-3200-5p/ATF4 Axis.

Oxidative medicine and cellular longevity·2022
Same author

Effect of Programmed Nursing Plan Based on Thinking Map Guidance Mode on Hemodynamics and Intestinal Function Recovery of Patients Undergoing Endoscopic Retrograde Cholangiopancreatography.

Emergency medicine international·2022
Same author

In vivo non-invasive confocal fluorescence imaging beyond 1,700 nm using superconducting nanowire single-photon detectors.

Nature nanotechnology·2022
Same author

Primary signet ring cell carcinoma of the appendix: An interesting case.

The American journal of the medical sciences·2022
Same author

MYC drives autophagy to adapt to stress in Penaeus vannamei.

Fish & shellfish immunology·2022
JoVE
x logofacebook logolinkedin logoyoutube logo
ACERCA DE JoVE
Visión GeneralLiderazgoBlogCentro de Ayuda JoVE
AUTORES
Proceso de PublicaciónConsejo EditorialAlcance y PolíticasRevisión por ParesPreguntas FrecuentesEnviar
BIBLIOTECARIOS
TestimoniosSuscripcionesAccesoRecursosConsejo Asesor de BibliotecasPreguntas Frecuentes
INVESTIGACIÓN
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchivo
EDUCACIÓN
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualCentro de Recursos para ProfesoresSitio de Profesores
Términos y Condiciones de Uso
Política de Privacidad
Políticas

Video Experimental Relacionado

Updated: May 12, 2026

Fluorescence detection methods for microfluidic droplet platforms
14:16

Fluorescence detection methods for microfluidic droplet platforms

Published on: December 10, 2011

23.0K

Método de reconocimiento de estado de la piscina de fusión rápida basado en red de baja latencia.

Yang Lu, Xinyu Dong, Yiyue Fan

    Optics express
    |February 20, 2026
    PubMed
    Resumen
    Este resumen es generado por máquina.

    Este estudio introduce una red de aprendizaje profundo rápida y ligera para el reconocimiento en tiempo real del estado de la piscina de fusión en la fabricación aditiva de metales. El nuevo método reduce significativamente la latencia para mejorar el control de calidad.

    Más Videos Relacionados

    Rapid and Efficient Zebrafish Genotyping Using PCR with High-resolution Melt Analysis
    06:30

    Rapid and Efficient Zebrafish Genotyping Using PCR with High-resolution Melt Analysis

    Published on: February 5, 2014

    23.1K
    Tracking Single Proteins in Lipid Bilayers Using Fluorescence Microscopy
    08:39

    Tracking Single Proteins in Lipid Bilayers Using Fluorescence Microscopy

    Published on: December 12, 2025

    935

    Videos de Experimentos Relacionados

    Last Updated: May 12, 2026

    Fluorescence detection methods for microfluidic droplet platforms
    14:16

    Fluorescence detection methods for microfluidic droplet platforms

    Published on: December 10, 2011

    23.0K
    Rapid and Efficient Zebrafish Genotyping Using PCR with High-resolution Melt Analysis
    06:30

    Rapid and Efficient Zebrafish Genotyping Using PCR with High-resolution Melt Analysis

    Published on: February 5, 2014

    23.1K
    Tracking Single Proteins in Lipid Bilayers Using Fluorescence Microscopy
    08:39

    Tracking Single Proteins in Lipid Bilayers Using Fluorescence Microscopy

    Published on: December 12, 2025

    935

    Área de la Ciencia:

    • Ciencia de los materiales Ciencia de los materiales.
    • Fabricación Ingeniería de fabricación Ingeniería.
    • Visión por ordenador Visión por ordenador Visión por ordenador Visión por ordenador Visión por ordenador

    Sus antecedentes:

    • El reconocimiento en tiempo real del estado de la piscina de fusión es crítico para la fabricación aditiva de metales (MAM) de alta calidad.
    • Los métodos de aprendizaje profundo existentes para el reconocimiento de piscinas de fusión exhiben una alta latencia, lo que dificulta el monitoreo en tiempo real.
    • Existe la necesidad de una identificación más rápida y precisa del estado de la piscina de fusión en MAM.

    Objetivo del estudio:

    • Desarrollar una red neuronal convolucional (CNN) ligera y de baja latencia para el reconocimiento rápido del estado de la piscina de fusión.
    • Para mejorar la velocidad y la precisión del monitoreo de las piscinas de fusión en los procesos de deposición de fusión láser (LMD).
    • Para permitir el control de calidad en tiempo real en la fabricación aditiva.

    Principales métodos:

    • Diseñó una unidad de red fundamental de alta velocidad que utiliza un operador de convolución selectiva para mejorar la extracción de características espaciales.
    • Desarrolló una ligera arquitectura CNN que incorpora la unidad de red diseñada para un eficiente análisis de imágenes de la piscina de fusión.
    • Recogió un conjunto de datos de los estados de las piscinas de fusión utilizando un sistema de fabricación aditiva por deposición de fusión láser personalizado.

    Principales resultados:

    • La red de baja latencia propuesta logró una alta precisión de reconocimiento del estado de la piscina de fusión del 98,50%.
    • El método demostró un tiempo de ejecución significativamente reducido de solo 5.26 ms.
    • Los resultados experimentales confirman la superioridad del enfoque propuesto sobre los métodos existentes.

    Conclusiones:

    • El CNN ligero desarrollado ofrece una solución superior para el reconocimiento en tiempo real del estado de la piscina de fusión en MAM.
    • La baja latencia y la alta precisión del método son cruciales para un monitoreo efectivo en tiempo real y la garantía de calidad.
    • Este avance contribuye al desarrollo de procesos de fabricación aditiva más robustos y eficientes.