Jove
Visualize
Contáctanos
JoVE
x logofacebook logolinkedin logoyoutube logo
ACERCA DE JoVE
Visión GeneralLiderazgoBlogCentro de Ayuda JoVE
AUTORES
Proceso de PublicaciónConsejo EditorialAlcance y PolíticasRevisión por ParesPreguntas FrecuentesEnviar
BIBLIOTECARIOS
TestimoniosSuscripcionesAccesoRecursosConsejo Asesor de BibliotecasPreguntas Frecuentes
INVESTIGACIÓN
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchivo
EDUCACIÓN
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualCentro de Recursos para ProfesoresSitio de Profesores
Términos y Condiciones de Uso
Política de Privacidad
Políticas

Videos de Conceptos Relacionados

Ultrasound II: Endoscopic Ultrasound and FibroScan01:25

Ultrasound II: Endoscopic Ultrasound and FibroScan

818
Endoscopic Ultrasound (EUS) and FibroScan are valuable diagnostic tools in gastroenterology and hepatology, each with specific applications and techniques.
Endoscopic Ultrasound (EUS):
818

También podría leer

Artículos Relacionados

Artículos vinculados a este trabajo por autores compartidos, revista y gráfico de citas.

Ordenar por
Same author

Lagrangian deformation tracking for strain imaging.

Progress in biomedical engineering (Bristol, England)·2026
Same author

Geometry aware neural radiance fields for freehand ultrasound reconstruction.

Biomedical physics & engineering express·2026
Same author

3D Freehand Ultrasound Reconstruction of the Carotid Artery.

Ultrasound in medicine & biology·2026
Same author

Editorial Expression of Concern: Regulation of Dipeptidyl Peptidase IV in the Post-stroke Rat Brain and In Vitro Ischemia: Implications for Chemokine-Mediated Neural Progenitor Cell Migration and Angiogenesis.

Molecular neurobiology·2026
Same author

Introducing ARONG, A 3D Reconstruction Method for Highly Deformed Histology.

Journal of imaging informatics in medicine·2026
Same author

Comparison of 2D and 3D carotid plaque analysis and longitudinal <i>in vivo</i> ultrasound registration using 3D histology.

Journal of medical imaging (Bellingham, Wash.)·2026

Video Experimental Relacionado

Updated: Feb 22, 2026

Manufacturing Abdominal Aorta Hydrogel Tissue-Mimicking Phantoms for Ultrasound Elastography Validation
09:32

Manufacturing Abdominal Aorta Hydrogel Tissue-Mimicking Phantoms for Ultrasound Elastography Validation

Published on: September 19, 2018

16.1K

Autoelastografía de ultrasonido B-mode auto-supervisada utilizando SMURF

Zhiwei Zhang1, Maxwell J Kiernan2, Carol C Mitchell3

  • 1Department of Electrical and Computer Engineering, UW-Madison, United States.

Ultrasonics
|February 20, 2026
PubMed
Resumen

Este estudio presenta un nuevo método de aprendizaje profundo no supervisado, SMURF, para la elastografía de deformación por ultrasonido (USE) utilizando imágenes B-mode. SMURF estima con precisión el desplazamiento y la deformación lateral, ofreciendo un procesamiento más rápido para aplicaciones clínicas.

Palabras clave:
Aprendizaje profundoImagen de deformación LagrangianaFlujo ópticoElastografía de deformación por ultrasonido

Más Videos Relacionados

Monitoring the Wall Mechanics During Stent Deployment in a Vessel
08:28

Monitoring the Wall Mechanics During Stent Deployment in a Vessel

Published on: May 8, 2012

9.7K
High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
11:50

High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart

Published on: July 9, 2010

24.8K

Videos de Experimentos Relacionados

Last Updated: Feb 22, 2026

Manufacturing Abdominal Aorta Hydrogel Tissue-Mimicking Phantoms for Ultrasound Elastography Validation
09:32

Manufacturing Abdominal Aorta Hydrogel Tissue-Mimicking Phantoms for Ultrasound Elastography Validation

Published on: September 19, 2018

16.1K
Monitoring the Wall Mechanics During Stent Deployment in a Vessel
08:28

Monitoring the Wall Mechanics During Stent Deployment in a Vessel

Published on: May 8, 2012

9.7K
High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
11:50

High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart

Published on: July 9, 2010

24.8K

Área de la Ciencia:

  • Imágenes médicas
  • Ingeniería biomédica
  • Aprendizaje automático

Sus antecedentes:

  • La elastografía de deformación por ultrasonido (USE) es crucial para la caracterización de tejidos, pero la estimación del desplazamiento lateral sigue siendo un desafío.
  • Los sistemas clínicos a menudo solo proporcionan imágenes B-mode, lo que limita la aplicación de los métodos USE existentes.
  • Las redes de aprendizaje profundo no supervisadas (DLN) requieren grandes conjuntos de datos, y los datos B-mode pueden abordar esto para la traducción clínica.

Objetivo del estudio:

  • Explorar el uso de SMURF (Self-Teaching Multi-Frame Unsupervised Recurrent All-Pairs Field Transform) para la elastografía de deformación por ultrasonido (USE).
  • Estimar los componentes del tensor de deformación axial y lateral utilizando aprendizaje profundo no supervisado en bucles de imágenes B-mode.
  • Evaluar el rendimiento de SMURF en comparación con los métodos tradicionales para imágenes in vivo.

Principales métodos:

  • Se reentrenó la red RAFT con supervisión de línea base en conjuntos de datos simulados y experimentales B-mode.
  • Se aplicó entrenamiento no supervisado SMURF en conjuntos de datos experimentales B-mode e in vivo.
  • Se utilizaron volúmenes de costos de cuatro dimensiones (4D) para la estimación de desplazamiento y deformación.

Principales resultados:

  • El modelo RAFT afinado con SMURF no supervisado logró una precisión y exactitud comparables en la estimación de desplazamiento y deformación con los métodos tradicionales, particularmente en la dirección lateral.
  • SMURF demostró tiempos de procesamiento significativamente más rápidos, con una mejora del 78% sobre el método de imagen de deformación carotídea Lagrangiana (LCSI) basado en GPU.
  • El método mostró potencial para USE Lagrangiana en tiempo real en estudios clínicos.

Conclusiones:

  • Las técnicas de aprendizaje profundo no supervisado, como SMURF, son efectivas para USE en conjuntos de datos B-mode.
  • SMURF ofrece una solución prometedora para la estimación precisa y eficiente del desplazamiento y la deformación lateral en USE.
  • Este enfoque facilita una aplicación clínica más amplia de USE, permitiendo potencialmente imágenes en tiempo real.