Jove
Visualize
Contáctanos
JoVE
x logofacebook logolinkedin logoyoutube logo
ACERCA DE JoVE
Visión GeneralLiderazgoBlogCentro de Ayuda JoVE
AUTORES
Proceso de PublicaciónConsejo EditorialAlcance y PolíticasRevisión por ParesPreguntas FrecuentesEnviar
BIBLIOTECARIOS
TestimoniosSuscripcionesAccesoRecursosConsejo Asesor de BibliotecasPreguntas Frecuentes
INVESTIGACIÓN
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchivo
EDUCACIÓN
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualCentro de Recursos para ProfesoresSitio de Profesores
Términos y Condiciones de Uso
Política de Privacidad
Políticas

Videos de Conceptos Relacionados

Raman Spectroscopy Instrumentation: Overview01:26

Raman Spectroscopy Instrumentation: Overview

1.4K
A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
1.4K

También podría leer

Artículos Relacionados

Artículos vinculados a este trabajo por autores compartidos, revista y gráfico de citas.

Ordenar por
Same author

Mid-Infrared Sensing and Ultrafast Photoresponse in Silicon-Based Plasmonic Detectors.

ACS photonics·2026
Same author

Broadband dispersion-engineered Bragg grating mirrors for integrated side-coupled Fabry-Pérot resonators.

Scientific reports·2026
Same author

Micro-ring resonator-assisted photothermal spectroscopy with integrated pump beam.

Optics letters·2026
Same author

Investigating Spectral Biomarker Candidates for Migratory Potential in Cancer Cells Using Micro-FTIR and O‑PTIR Spectroscopy.

ACS measurement science au·2026
Same author

Broadband refractive index sensor using photonic molecule architecture with subwavelength grating mirrors on silicon nitride.

Optics express·2026
Same author

Engineered fano resonances in a compact Si<sub>3</sub>N<sub>4</sub> photonic crystal nanobeam-microring platform for multi-cladding environments.

Scientific reports·2026

Video Experimental Relacionado

Updated: Feb 24, 2026

Terahertz Microfluidic Sensing Using a Parallel-plate Waveguide Sensor
07:28

Terahertz Microfluidic Sensing Using a Parallel-plate Waveguide Sensor

Published on: August 30, 2012

11.2K

Sensor de índice de refracción basado en un resonador de microanillo de Si₃N₄ para muestras líquidas: Comparación de

Daniela Tomasetig1, Jesus Hernan Mendoza-Castro1, Silvia Schobesberger2

  • 1TU Wien, Institute of Chemical Technologies and Analytics, Getreidemarkt 9/164, Vienna 1060, Austria.

ACS measurement science au
|February 23, 2026
PubMed
Resumen

Este estudio presenta un resonador de microanillo (MRR) de nitruro de silicio para la detección de índice de refracción (RI) en tiempo real en sistemas microfluídicos. El detector a escala de chip ofrece alta sensibilidad y velocidad, superando a los dispositivos comerciales para el análisis de líquidos.

Palabras clave:
microfluídicaresonador de microanillodetección en chipdetección de índice de refracciónazúcares

Más Videos Relacionados

Synthesis and Operation of Fluorescent-core Microcavities for Refractometric Sensing
08:12

Synthesis and Operation of Fluorescent-core Microcavities for Refractometric Sensing

Published on: March 13, 2013

13.2K
Implementation of a Reference Interferometer for Nanodetection
16:11

Implementation of a Reference Interferometer for Nanodetection

Published on: April 26, 2014

9.8K

Videos de Experimentos Relacionados

Last Updated: Feb 24, 2026

Terahertz Microfluidic Sensing Using a Parallel-plate Waveguide Sensor
07:28

Terahertz Microfluidic Sensing Using a Parallel-plate Waveguide Sensor

Published on: August 30, 2012

11.2K
Synthesis and Operation of Fluorescent-core Microcavities for Refractometric Sensing
08:12

Synthesis and Operation of Fluorescent-core Microcavities for Refractometric Sensing

Published on: March 13, 2013

13.2K
Implementation of a Reference Interferometer for Nanodetection
16:11

Implementation of a Reference Interferometer for Nanodetection

Published on: April 26, 2014

9.8K

Área de la Ciencia:

  • Fotónica y Microfluídica; Química Analítica; Biosensores

Sus antecedentes:

  • La medición del índice de refracción (RI) es crucial para la detección de líquidos, pero los detectores comerciales tienen limitaciones en rango y velocidad.
  • Los resonadores de microanillo (MRR) integrados con microfluídica ofrecen un rendimiento mejorado de detección de RI con bajo volumen de muestra y mayor rango dinámico.

Objetivo del estudio:

  • Desarrollar y demostrar un detector de índice de refracción compacto y a escala de chip utilizando un resonador de microanillo (MRR) de nitruro de silicio (Si₃N₄) integrado en un sistema microfluídico.
  • Comparar dos modalidades de interrogación para la detección de líquidos de flujo continuo: escaneo de longitud de onda de resonancia y sondeo de longitud de onda fija.
  • Evaluar el rendimiento del dispositivo para mediciones en tiempo real bajo condiciones de flujo dinámico y su aplicabilidad en separaciones cromatográficas.

Principales métodos:

  • Fabricación de un resonador de microanillo (MRR) de nitruro de silicio (Si₃N₄) integrado con un sistema microfluídico de bajo volumen.
  • Comparación experimental de escaneo de longitud de onda de resonancia y sondeo de longitud de onda fija para interrogar el MRR.
  • Evaluación comparativa del dispositivo con un detector de RI comercial utilizando soluciones de glucosa.
  • Demostración de la capacidad del sensor para resolver picos transitorios de RI durante la separación isocrática de cuatro azúcares.

Principales resultados:

  • El detector basado en MRR de Si₃N₄ logró una alta sensibilidad (113 nm/RIU) y un bajo límite de detección (sLOD de 2.3 × 10⁻⁶ RIU).
  • El dispositivo demostró operación en tiempo real bajo condiciones de flujo dinámico, resolviendo con éxito picos transitorios de índice de refracción.
  • Aplicación exitosa en una separación isocrática de cuatro azúcares, mostrando su utilidad en el análisis cromatográfico.

Conclusiones:

  • Los MRR integrados de Si₃N₄ proporcionan una plataforma versátil y miniaturizada para la detección cuantitativa y de alta velocidad del índice de refracción en sistemas analíticos basados en flujo.
  • El detector de RI a escala de chip desarrollado ofrece un rendimiento mejorado en comparación con alternativas comerciales, particularmente para condiciones de flujo dinámico.
  • Esta tecnología tiene un potencial significativo para esquemas de detección avanzados y aplicaciones en ciencias de la separación y biosensores.