Video Experimental Relacionado
Updated: Feb 24, 2026

Hemodynamic Precision in the Neonatal Intensive Care Unit using Targeted Neonatal Echocardiography
Published on: January 27, 2023
Medición Automatizada de Ecocardiogramas Basada en Aprendizaje Profundo en Cardiopatías Pediátricas y Congénitas
Background:
Echocardiography (echo) is a cornerstone of pediatric cardiology, yet access to expert interpreters is limited worldwide, particularly in low-resource and rural settings. Artificial intelligence (AI) offers a mechanism to broadly deliver expert-level precision and standardize measurements, yet AI for comprehensive automated measurements in pediatric and congenital heart disease (CHD) echo remains underdeveloped.
Methods:
We created EchoFocus-Measure, an AI platform that automatically extracts 18 quantitative parameters and 10 qualitative assessments from full echo studies. The method extends a multi-task, view-agnostic architecture (PanEcho) with a study-level transformer to prioritize diagnostically informative views. Training (80%) and internal testing (20%) were performed on echos from Boston Children's Hospital (BCH), with external evaluation on outside referral studies. Left ventricular ejection fraction (LVEF) was the primary endpoint.
Results:
The internal cohort included 11.4 million videos from 217,435 echos (60,269 patients; median age 8.5 years; median LVEF 61%), and external validation encompassed 289,613 videos from 3,096 echos (2,506 patients; median age 3.5 years; median LVEF 62%). For LVEF, EchoFocus-Measure exhibited a median absolute error (MAE) of 2.8% internally and 3.8% externally, maintaining accuracy across infants (MAE 3.2%) and complex CHD lesions (e.g., MAE 4.0% for L-loop transposition of the great arteries). EchoFocus-Measure improved upon the PanEcho benchmark (MAE 7.5% for infants; 13.1% for L-loop transposition). Discrepant case (>50 th percentile error) adjudication of LVEF demonstrated that model errors (MAE 2.4%) were within human variability (MAE 3.7%). For qualitative measures, EchoFocus-Measure performed well internally (AUROC 0.88-0.95) and modestly externally (AUROC 0.73-0.86). Explainability analyses highlighted model focus on clinically appropriate echo views for LVEF estimation (apical four-chamber, parasternal short/long) and mitral regurgitation assessment (apical four-chamber color Doppler, parasternal short/long color Doppler).
Conclusions:
EchoFocus-Measure delivers rapid and reliable automated echo measurements across ages and lesions within diverse internal and real-world external cohorts, serving as a step toward scalable, global access to high-quality pediatric cardiovascular care.
Videos de Conceptos Relacionados
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion,...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...

