Aspectos técnicos y relevancia clínica de los dispositivos sin manguito para la medición de la presión arterial. Una
Gianfranco Parati1,2, Juan Eugenio Ochoa1, Ana Abreu3,4
1Dept of Cardiology, IRCCS San Luca Hospital, Istituto Auxologico Italiano, Milan, Italy.
Abstract:
Cuffless blood pressure (BP) monitoring devices represent a promising innovation in hypertension management. This scientific statement provides a comprehensive update on these emerging technologies, their specific validation requirements, their potential clinical applications, and their present and future challenges. These devices generate considerable interest by enabling noninvasive BP measurement without arterial occlusion, thereby eliminating the discomfort associated with traditional cuff-based monitoring, particularly during sleep. The technologies on which these devices are based comprise a heterogeneous group, primarily utilizing pulse wave propagation time or waveform analysis through contact or noncontact sensors. They can be categorized as continuous or intermittent, automated or manual, calibration-free or requiring cuff/demographic calibration, and wearable or stationary. This technological diversity necessitates validation protocols distinct from those used for conventional cuff-based monitors, with specific requirements for each device category. Potential clinical applications include widespread out-of-office BP monitoring, unbiased assessment of circadian BP patterns and BP variability, improved detection of nocturnal hypertension, enhanced treatment adherence and long-term BP control, and continuous monitoring in hospital settings. Additionally, their lower cost compared with conventional technologies could enhance the early detection of hypertension in resource-limited settings. However, due to insufficient accuracy validation, this scientific statement does not still recommend their use in clinical decisions, in line with international guidelines not recommending their use in hypertension management. Key challenges ahead include developing standardized validation protocols, establishing normative BP data, manage the resulting burden on clinicians in handling huge volumes of data, exploring additional hemodynamic parameters, and advancing sensor technology, mathematical models, and algorithms.
Más Videos Relacionados
Videos de Conceptos Relacionados
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Errors occurring during blood pressure monitoring
Several factors...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Pre-Procedural Guidelines for Assessing Blood Pressure
Measurement of Blood Pressure