Video Experimental Relacionado
Updated: Feb 27, 2026

A Coupled Experiment-finite Element Modeling Methodology for Assessing High Strain Rate Mechanical Response of Soft Biomaterials
Published on: May 18, 2015
Efecto de la regularización en el modelado y simulación eficientes de compuestos bioinspirados utilizando el método
Md Jalal Uddin Rumi1, Xiaowei Zeng1
1Department of Mechanical, Aerospace & Industrial Engineering, University of Texas at San Antonio, San Antonio, TX 78249, USA.
Abstract:
Tessellation-based polyhedral microstructures derived from Voronoi and Laguerre constructions provide a realistic geometric foundation for modeling bioinspired organic-inorganic composites with interfacial fracture. However, even after extensive centroidal relaxation, such tessellations retain numerous lower-dimensional geometric degeneracies-very short edges and small or sliver-like faces-that severely hinder volumetric meshing and render large-scale cohesive-zone simulations computationally impractical. In this work, we employ a geometric regularization step that enforces a minimum admissible feature length prior to meshing and systematically quantify its impact on downstream performance in finite element discretization and cohesive fracture simulation. By eliminating geometric features below the prescribed length scale while preserving grain topology and morphology, the regularized tessellations exhibit sharply improved edge-length and face-diameter distributions and become readily meshable at practical resolutions. When applied to a 3D bioinspired organic-inorganic composite with cohesive interfaces, the regularized geometry reduces volumetric and cohesive element counts nearly fivefold and increases the explicit stable time increment by approximately four orders of magnitude, transforming an otherwise diverging analysis into a robust simulation that converges to the prescribed deformation. These results demonstrate that the prescribed geometric regularization step is not merely a preprocessing refinement but a critical enabling step for efficient and large-scale cohesive fracture simulations of tessellation-based bioinspired composites.
Más Videos Relacionados
13:07Optical Coherence Tomography Based Biomechanical Fluid-Structure Interaction Analysis of Coronary Atherosclerosis Progression
Published on: January 15, 2022
09:54Author Spotlight: Enhancing Fiber Composite Laminate Quality with the Wet Hand Lay-Up/Vacuum Bag Process
Published on: June 30, 2023
Videos de Conceptos Relacionados
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Dynamic Modulus of Elasticity of Concrete
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by a...
Design Example: Managing Concrete Workability