Video Experimental Relacionado
Updated: Oct 13, 2026

10:35
Bringing the Visible Universe into Focus with Robo-AO
Published on: February 12, 2013
HST imágenes en el ultravioleta lejano de Júpiter durante los impactos del cometa Shoemaker-Levy 9 9
J T Clarke1, R Prangé, G E Ballester
1Space Physics Research Laboratory, University of Michigan, Ann Arbor 48109.
Resumen
Las imágenes ultravioletas del Telescopio Espacial Hubble revelan que Júpiter es Júpiter.
Área de la Ciencia:
- Ciencias planetarias Ciencias planetarias.
- La astronomía es la astronomía.
- La astrofísica es la astrofísica.
Sus antecedentes:
- El cometa Shoemaker-Levy 9 impactó con Júpiter en julio de 1994, proporcionando una oportunidad única para estudiar la atmósfera de Júpiter.
- Las observaciones anteriores de impactos en gigantes gaseosos fueron limitadas en el rango espectral y la resolución temporal.
Objetivo del estudio:
- Para analizar la respuesta atmosférica de Júpiter a los impactos de Shoemaker-Levy 9 utilizando imágenes en el ultravioleta lejano (FUV).
- Para comparar las observaciones de FUV con longitudes de onda más largas para comprender la altitud y las propiedades de los aerosoles generados por el impacto.
- Para investigar posibles cambios en la actividad auroral de Júpiter asociada con los impactos.
Principales métodos:
- Utilizó las capacidades de imagen FUV del Telescopio Espacial Hubble para capturar imágenes de alta resolución de Júpiter durante y después de los impactos.
- Analizó la evolución temporal de los sitios de impacto en el espectro FUV.
- Las observaciones FUV correlacionadas con las emisiones aurorales y la actividad auroral global.
Principales resultados:
- Las regiones de impacto mostraron un oscurecimiento en las imágenes FUV dentro de las 2-3 horas posteriores al impacto, persistiendo más tiempo y extendiéndose más allá de las características en longitudes de onda visibles.
- Esto sugiere la presencia de gases o aerosoles más extendidos, más absorbentes y de mayor altitud que absorben los rayos ultravioleta en comparación con los absorbentes de luz visible.
- Se detectaron emisiones aurorales transitorias cerca del conjugado magnético del sitio de impacto K; la actividad auroral global fue más débil que el promedio.
Conclusiones:
- Las observaciones del FUV revelan capas atmosféricas distintas afectadas por los impactos, con depósitos significativos de aerosoles o gases a gran altitud.
- Los impactos influyeron en la magnetosfera de Júpiter, lo que condujo a mejoras localizadas de las auroras y una disminución general en el brillo de las auroras globales.
- Este estudio destaca la utilidad de las observaciones de FUV para sondear la dinámica atmosférica y la composición durante los impactos extraterrestres.
Videos de Conceptos Relacionados
Emission Spectra
When solids, liquids, or condensed gases are heated sufficiently, they radiate some of the excess energy as light. Photons produced in this manner have a range of energies, and thereby produce a continuous spectrum in which an unbroken series of wavelengths is present.
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
Ultraviolet–visible (UV–visible or UV–Vis) spectroscopy is an analytical technique that investigates the interaction between matter and UV–Vis light within the electromagnetic spectrum. This method is widely used for its versatility, simplicity, and relatively quick data acquisition, making it valuable for both qualitative and quantitative analysis. When UV–Vis radiation passes through a material, molecules absorb light depending on the energy required for electronic transitions. As a result...
X-ray Imaging
German physicist Wilhelm Röntgen (1845–1923) was experimenting with electrical current when he discovered that a mysterious and invisible "ray" would pass through his flesh but leave an outline of his bones on a screen coated with a metal compound. In 1895, Röntgen made the first durable record of the internal parts of a living human: an "X-ray" image (as it came to be called) of his wife’s hand. Scientists worldwide quickly began their own experiments with X-rays, and by 1900, X-ray was widely...
Atomic Emission Spectroscopy: Instrumentation
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
Atomic Emission Spectroscopy: Interference
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
Atomic Emission Spectroscopy: Lab
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...

