Jove
Visualize
お問い合わせ
JoVE
x logofacebook logolinkedin logoyoutube logo
JoVEについて
概要リーダーシップブログJoVEヘルプセンター
著者向け
出版プロセス編集委員会範囲と方針査読よくある質問投稿
図書館員向け
推薦の声購読アクセスリソース図書館諮問委員会よくある質問
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experimentsアーカイブ
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教員リソースセンター教員サイト
利用規約
プライバシーポリシー
ポリシー

関連する概念動画

UV–Vis Spectrometers01:14

UV–Vis Spectrometers

The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell. Samples for...
IR Spectrometers01:25

IR Spectrometers

There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
Fluorescence and Phosphorescence: Instrumentation01:25

Fluorescence and Phosphorescence: Instrumentation

Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
Raman Spectroscopy Instrumentation: Overview01:26

Raman Spectroscopy Instrumentation: Overview

A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
Atomic Absorption Spectroscopy: Instrumentation01:22

Atomic Absorption Spectroscopy: Instrumentation

An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation01:26

Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation

Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy  (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.

こちらも読む

関連記事

共著者、ジャーナル、引用グラフによってこの研究に関連する記事。

並び替え
Same author

Sculpted-multilayer optical effects in two species of Papilio butterfly.

Applied optics·2008
関連記事をすべて見る

関連する実験動画

Updated: Jun 24, 2026

Whole Cell Patch Clamp for Investigating the Mechanisms of Infrared Neural Stimulation
08:58

Whole Cell Patch Clamp for Investigating the Mechanisms of Infrared Neural Stimulation

Published on: July 31, 2013

光学:光感知器を装備しています.

R Sambles

    Nature
    |August 24, 2001
    PubMed
    まとめ

    No abstract available in PubMed .

    さらに関連する動画

    Excitation-Scanning Hyperspectral Imaging Microscopy to Efficiently Discriminate Fluorescence Signals
    07:34

    Excitation-Scanning Hyperspectral Imaging Microscopy to Efficiently Discriminate Fluorescence Signals

    Published on: August 22, 2019

    Light-Induced In Situ Transmission Electron Microscopy for Observation of the Liquid-Soft Matter Interaction
    05:33

    Light-Induced In Situ Transmission Electron Microscopy for Observation of the Liquid-Soft Matter Interaction

    Published on: July 26, 2022

    関連する実験動画

    Last Updated: Jun 24, 2026

    Whole Cell Patch Clamp for Investigating the Mechanisms of Infrared Neural Stimulation
    08:58

    Whole Cell Patch Clamp for Investigating the Mechanisms of Infrared Neural Stimulation

    Published on: July 31, 2013

    Excitation-Scanning Hyperspectral Imaging Microscopy to Efficiently Discriminate Fluorescence Signals
    07:34

    Excitation-Scanning Hyperspectral Imaging Microscopy to Efficiently Discriminate Fluorescence Signals

    Published on: August 22, 2019

    Light-Induced In Situ Transmission Electron Microscopy for Observation of the Liquid-Soft Matter Interaction
    05:33

    Light-Induced In Situ Transmission Electron Microscopy for Observation of the Liquid-Soft Matter Interaction

    Published on: July 26, 2022