関連する実験動画
Updated: Jul 16, 2026

10:52
Direct Imaging of Laser-driven Ultrafast Molecular Rotation
Published on: February 4, 2017
フェムト秒のレーザーパルスを使用して,サポートされた脂質バイレイヤのダイナミックな再分割
Andreia M Smith1, Thomas Huser, Atul N Parikh
1Applied Science, Biophysics, and Internal Medicine Graduate Programs, and NSF Center for Biophotonics, Science and Technology, University of California-Davis, Davis, CA 95619, USA.
Journal of the American Chemical Society
|February 10, 2007
まとめ
No abstract available in PubMed .
関連する概念動画
Confocal Fluorescence Microscopy
Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...
Protein Dynamics in Living Cells
Different fluorescence-based techniques are used to study the protein dynamics in living cells. These techniques include FRAP, FRET, and PET.
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Fluorescent recovery after photobleaching (FRAP) is a fluorescent-protein-based detection technique used to quantify protein movement rates within the cell. This method exposes a small portion of the cell to an intense laser beam. The laser beam causes permanent photobleaching of the fluorophore-tagged proteins in the exposed region. As the bleached...
Super-resolution Fluorescence Microscopy
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been developed.
Double Resonance Techniques: Overview
Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
Spin decoupling is usually achieved by...

