Jove
Visualize
お問い合わせ
JoVE
x logofacebook logolinkedin logoyoutube logo
JoVEについて
概要リーダーシップブログJoVEヘルプセンター
著者向け
出版プロセス編集委員会範囲と方針査読よくある質問投稿
図書館員向け
推薦の声購読アクセスリソース図書館諮問委員会よくある質問
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experimentsアーカイブ
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教員リソースセンター教員サイト
利用規約
プライバシーポリシー
ポリシー

関連する概念動画

Biological Effects of Radiation02:59

Biological Effects of Radiation

All radioactive nuclides emit high-energy particles or electromagnetic waves. When this radiation encounters living cells, it can cause heating, break chemical bonds, or ionize molecules. The most serious biological damage results when these radioactive emissions fragment or ionize molecules. For example, α and β particles emitted from nuclear decay reactions possess much higher energies than ordinary chemical bond energies. When these particles strike and penetrate matter, they produce ions...
Absorption of Radiation01:05

Absorption of Radiation

The rate of heat transfer by emitted radiation is described by the Stefan-Boltzmann law of radiation:
Atomic Emission Spectroscopy: Interference01:30

Atomic Emission Spectroscopy: Interference

In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
Atomic Fluorescence Spectroscopy01:29

Atomic Fluorescence Spectroscopy

Atomic fluorescence spectroscopy (AFS) is an analytical technique that involves the electronic transitions of atoms in a flame, furnace, or plasma being excited by electromagnetic (EM) radiation. When these atoms absorb energy, they become excited and subsequently release energy as they return to their original state. This emitted light, or "fluorescence," is observed at a right angle to the incident beam. Both absorption and emission processes transpire at distinct wavelengths, which are...
Insulation Coordination01:23

Insulation Coordination

Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times for...
Electronic Distance Measuring Instruments01:30

Electronic Distance Measuring Instruments

Electronic Distance Measuring Instruments (EDMs) are essential tools in modern surveying, offering precise distance measurements by emitting electromagnetic signals and calculating the time required for these signals to travel to a target and return. Two primary types of signals are used in EDMs — light waves and microwaves — each suited to specific environmental and distance requirements. Light-wave-based EDMs utilize either infrared or laser light, providing high accuracy over short distances...

こちらも読む

関連記事

共著者、ジャーナル、引用グラフによってこの研究に関連する記事。

並び替え
Same author

Radioisotopes in the study of mineral metabolism.

Progress in nuclear energy. Series 6 Biological sciences·2014
Same author

Cobalt metabolism studies; partition of radioactive cobalt by a rumen fistula cow.

The Journal of nutrition·2010
Same author

Cobalt metabolism studies; radioactive cobalt procedures with rats and cattle.

Archives of biochemistry·2010
Same author

Cobalt metabolism studies; excretion and tissue distribution of radioactive cobalt administered to cattle.

Archives of biochemistry·2010
Same author

Risk: a pragmatic de minimis approach.

Science (New York, N.Y.)·1979
Same author

Science and regulatory policy.

Science (New York, N.Y.)·1979

関連する実験動画

Updated: Jun 24, 2026

Diffuse Optical Spectroscopy for the Quantitative Assessment of Acute Ionizing Radiation Induced Skin Toxicity Using a Mouse Model
06:21

Diffuse Optical Spectroscopy for the Quantitative Assessment of Acute Ionizing Radiation Induced Skin Toxicity Using a Mouse Model

Published on: May 27, 2016

放射能基準とは

C L Comar

    Science (New York, N.Y.)
    |August 17, 1973
    PubMed
    まとめ

    No abstract available in PubMed .

    さらに関連する動画

    Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation
    10:33

    Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation

    Published on: September 4, 2017

    Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities
    06:51

    Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities

    Published on: February 20, 2021

    関連する実験動画

    Last Updated: Jun 24, 2026

    Diffuse Optical Spectroscopy for the Quantitative Assessment of Acute Ionizing Radiation Induced Skin Toxicity Using a Mouse Model
    06:21

    Diffuse Optical Spectroscopy for the Quantitative Assessment of Acute Ionizing Radiation Induced Skin Toxicity Using a Mouse Model

    Published on: May 27, 2016

    Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation
    10:33

    Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation

    Published on: September 4, 2017

    Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities
    06:51

    Dosimetry for Cell Irradiation using Orthovoltage (40-300 kV) X-Ray Facilities

    Published on: February 20, 2021