Jove
Visualize
お問い合わせ
JoVE
x logofacebook logolinkedin logoyoutube logo
JoVEについて
概要リーダーシップブログJoVEヘルプセンター
著者向け
出版プロセス編集委員会範囲と方針査読よくある質問投稿
図書館員向け
推薦の声購読アクセスリソース図書館諮問委員会よくある質問
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experimentsアーカイブ
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教員リソースセンター教員サイト
利用規約
プライバシーポリシー
ポリシー

関連する概念動画

Overcurrent Relays01:26

Overcurrent Relays

Overcurrent relays, crucial for circuit protection, are connected to the secondary current of a current transformer. There are two primary types of overcurrent relays: instantaneous and time-delay.
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
Differential Relays01:20

Differential Relays

Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
Directional Relays01:25

Directional Relays

Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
Line Protection with Impedance Relays01:27

Line Protection with Impedance Relays

Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Pilot and Numeric Relaying01:21

Pilot and Numeric Relaying

Pilot relaying is a type of differential protection used in power systems. It compares electrical quantities at the terminals of equipment via a communication channel instead of direct relay interconnection. This method is essential for transmission lines where the terminals are far apart, typically up to 80 km for lines with 69 to 115 kV ratings. Four types of communication channels are used for pilot relaying:
Reclosers and Fuses01:26

Reclosers and Fuses

Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...

こちらも読む

関連記事

共著者、ジャーナル、引用グラフによってこの研究に関連する記事。

並び替え
Same author

Mechanisms of glucose intolerance in cystic fibrosis.

Diabetic medicine : a journal of the British Diabetic Association·2009
Same author

Urinary tract infection after stroke.

QJM : monthly journal of the Association of Physicians·2009
Same author

Connexin-specific cell-to-cell transfer of short interfering RNA by gap junctions.

The Journal of physiology·2005
Same author

E-mentoring: does it have a place in medicine?

Postgraduate medical journal·2005
Same author

Renal impairment in cystic fibrosis patients due to repeated intravenous aminoglycoside use.

Pediatric pulmonology·2004
Same author

High-resolution record of Northern Hemisphere climate extending into the last interglacial period.

Nature·2004

関連する実験動画

Updated: Jul 12, 2026

Autonomous and Rechargeable Microneurostimulator Endoscopically Implantable into the Submucosa
08:17

Autonomous and Rechargeable Microneurostimulator Endoscopically Implantable into the Submucosa

Published on: September 27, 2018

改善された特性を持つ電子リレー

R C Hawes, H Miller

    Science (New York, N.Y.)
    |January 3, 1941
    PubMed
    まとめ

    No abstract available in PubMed .

    関連する実験動画

    Last Updated: Jul 12, 2026

    Autonomous and Rechargeable Microneurostimulator Endoscopically Implantable into the Submucosa
    08:17

    Autonomous and Rechargeable Microneurostimulator Endoscopically Implantable into the Submucosa

    Published on: September 27, 2018