関連する概念動画
Two-Dimensional Microscopy in Microbiology
1.0K
Two-dimensional (2D) microscopy encompasses a range of optical techniques that capture images within a single focal plane, offering detailed representations of microscopic structures. These techniques are essential in biological and medical research, enabling the visualization of cellular and subcellular structures with different levels of contrast and specificity.There are several major types of 2D microscopy, each with strengths and applications.Bright-Field MicroscopyBright-field microscopy...
1.0K
Three-Dimensional Microscopy in Microbiology
740
Three-dimensional imaging techniques are essential in cell biology, allowing researchers to visualize intricate cellular structures with high resolution. Two prominent methods, Differential Interference Contrast Microscopy (DIC) and Confocal Scanning Laser Microscopy (CSLM), provide distinct advantages for imaging live and thick specimens, respectively.Differential Interference Contrast MicroscopyDIC microscopy enhances contrast in transparent, unstained samples by converting phase...
740
Phase Contrast and Differential Interference Contrast Microscopy
11.9K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
11.9K
Confocal Fluorescence Microscopy
19.9K
Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...
19.9K
Super-resolution Fluorescence Microscopy
12.1K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
12.1K
Imaging Biological Samples with Optical Microscopy
8.7K
Optical microscopy uses optic principles to provide detailed images of samples. Antonie van Leeuwenhoek designed the first compound optical microscope in the 17th century to visualize blood cells, bacteria, and yeast cells. In 1830, Joseph Jackson Lister created an essentially modern light microscope. The 20th century saw the development of microscopes with enhanced magnification and resolution.
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
8.7K
こちらも読む
関連記事
共著者、ジャーナル、引用グラフによってこの研究に関連する記事。
並び替え
Same author
Blood counts of newborn infants in relation to icterus neonatorum.
Archives of disease in childhood·2010
Same author
Banti's syndrome in childhood: A report of four cases.
Archives of disease in childhood·2010
Same author
Evolution of the Fermi surface across a magnetic order-disorder transition in the two-dimensional Kondo lattice model: a dynamical cluster approach.
Physical review letters·2008
Same author
Is 44-hour better than 24-hour ambulatory blood pressure monitoring in hemodialysis?
Kidney & blood pressure research·2006
Same journal
Author Correction: Synthesis of enantioenriched atropisomers by biocatalytic deracemization.
Nature·2026


