Jove
Visualize
お問い合わせ
JoVE
x logofacebook logolinkedin logoyoutube logo
JoVEについて
概要リーダーシップブログJoVEヘルプセンター
著者向け
出版プロセス編集委員会範囲と方針査読よくある質問投稿
図書館員向け
推薦の声購読アクセスリソース図書館諮問委員会よくある質問
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experimentsアーカイブ
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教員リソースセンター教員サイト
利用規約
プライバシーポリシー
ポリシー

関連する概念動画

Accuracy and Precision01:52

Accuracy and Precision

2.9K
2.9K
Accuracy and Precision01:52

Accuracy and Precision

12.6K
Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value.  Highly accurate...
12.6K
Common Leveling Mistakes and Errors01:17

Common Leveling Mistakes and Errors

703
A survey team is tasked with determining the elevation difference between points Point A and Point B, separated by uneven terrain. They use a leveling instrument and a leveling rod.Common MistakesMisreading the Rod: During a backsight reading at Point A, the instrumentman observes the rod partially obscured by tall grass. Instead of reading 1.135 m, they mistakenly record 1.735 m due to the misalignment of the crosshair with the wrong graduation. This error adds 0.600 m to all subsequent...
703
Errors and Mistakes in Surveying01:19

Errors and Mistakes in Surveying

1.1K
Errors and mistakes in surveying refer to inaccuracies in measurements and data recording. The errors are deviations from the actual value caused by human sensory limitations, equipment flaws, or environmental effects. These errors are typically unintentional and can result from the inherent imperfections in the instruments used, atmospheric conditions, or the observer’s inability to perceive exact measurements. On the other hand, mistakes are caused by the surveyor's lack of...
1.1K
Errors in Taping01:18

Errors in Taping

509
Errors in taping arise from multiple factors that can significantly impact measurement accuracy in surveying. Misalignment of the tape, often due to human error, is one primary source. A skilled rear tapeman, using a telescope, can help correct alignment by guiding the head tapeman; however, human limitations still lead to small inaccuracies. These errors may include misplacement of pins or inaccurate tape readings due to common visual confusions, such as mistaking a six for a nine. Such...
509
Uncertainty in Measurement: Accuracy and Precision03:37

Uncertainty in Measurement: Accuracy and Precision

94.0K
Scientists typically make repeated measurements of a quantity to ensure the quality of their findings and to evaluate both the precision and the accuracy of their results. Measurements are said to be precise if they yield very similar results when repeated in the same manner. A measurement is considered accurate if it yields a result that is very close to the true or the accepted value. Precise values agree with each other; accurate values agree with a true value. 
94.0K

こちらも読む

関連記事

共著者、ジャーナル、引用グラフによってこの研究に関連する記事。

並び替え
Same author

Tweak makes U.S. nukes more precise-and deadlier.

Science (New York, N.Y.)·2017
Same author

An experiment in zero parenting.

Science (New York, N.Y.)·2014
Same author

Tax man's gloomy message: the rich will get richer.

Science (New York, N.Y.)·2014
Same author

The veteran: Russ Hille.

Science (New York, N.Y.)·2014
Same author

Breast cancer. Dare to do less.

Science (New York, N.Y.)·2014
Same author

Intellectual property. Historic patent on embryonic stem cells faces scrutiny.

Science (New York, N.Y.)·2014

関連する実験動画

Updated: May 5, 2026

Evaluating Targeting Accuracy in the Focal Plane for an Ultrasound-guided High-intensity Focused Ultrasound Phased-array System
08:08

Evaluating Targeting Accuracy in the Focal Plane for an Ultrasound-guided High-intensity Focused Ultrasound Phased-array System

Published on: March 6, 2019

4.5K

標識を逃した.

Eliot Marshall

    Science (New York, N.Y.)
    |November 23, 2013
    PubMed
    まとめ

    No abstract available in PubMed .

    さらに関連する動画

    Making Sense of Listening: The IMAP Test Battery
    11:25

    Making Sense of Listening: The IMAP Test Battery

    Published on: October 11, 2010

    17.5K
    Utilizing vmTracking to Improve the Accuracy of Multi-Animal Pose Estimation in Rodent Social Behavior Studies
    07:34

    Utilizing vmTracking to Improve the Accuracy of Multi-Animal Pose Estimation in Rodent Social Behavior Studies

    Published on: November 7, 2025

    557

    関連する実験動画

    Last Updated: May 5, 2026

    Evaluating Targeting Accuracy in the Focal Plane for an Ultrasound-guided High-intensity Focused Ultrasound Phased-array System
    08:08

    Evaluating Targeting Accuracy in the Focal Plane for an Ultrasound-guided High-intensity Focused Ultrasound Phased-array System

    Published on: March 6, 2019

    4.5K
    Making Sense of Listening: The IMAP Test Battery
    11:25

    Making Sense of Listening: The IMAP Test Battery

    Published on: October 11, 2010

    17.5K
    Utilizing vmTracking to Improve the Accuracy of Multi-Animal Pose Estimation in Rodent Social Behavior Studies
    07:34

    Utilizing vmTracking to Improve the Accuracy of Multi-Animal Pose Estimation in Rodent Social Behavior Studies

    Published on: November 7, 2025

    557