化学的に調節するセンシタイザーによって達成される1.08eVのアンチストークスシフトによる効率的なトリプレット・トリプレット・アニヒレーション・アップコンバージョン

Chunying Fan1, Lingling Wei1, Tong Niu1

  • 1Key Laboratory of Green Chemistry & Technology, College of Chemistry, State Key Laboratory of Biotherapy, West China Medical Center, and Healthy Food Evaluation Research Center , Sichuan University , 29 Wangjiang Road , Chengdu 610064 , China.

まとめ

新しいプラチナ複合体は,深赤から青のスペクトル全体で効率的なトリプル-トリプルアニヒレーションアップコンバージョン (TTA-UC) を可能にします. この画期的な発明は エネルギー損失を最小限に抑え 太陽光発電の応用に 期待を寄せています

関連する概念動画

Triplet Fusion Upconversion Nanocapsule Synthesis08:36

Triplet Fusion Upconversion Nanocapsule Synthesis

This protocol details the synthesis of upconversion nanocapsules for subsequent use in photopolymerizable resins for triplet fusion upconversion-facilitated volumetric 3D...
2.9K
Integrating a Triplet-triplet Annihilation Up-conversion System to Enhance Dye-sensitized Solar Cell Response to Sub-bandgap Light11:26

Integrating a Triplet-triplet Annihilation Up-conversion System to Enhance Dye-sensitized Solar Cell Response to Sub-bandgap Light

An integrated device, incorporating a dye-sensitized solar cell and triplet-triplet annihilation up-conversion unit was produced, affording enhanced light harvesting, from a wider section of the solar spectrum. Under modest irradiation levels a significantly enhanced response to low energy photons was demonstrated, yielding a record figure of merit for dye-sensitized solar...
13.1K
Tuning Degradation to Achieve Specific and Efficient Protein Depletion05:11

Tuning Degradation to Achieve Specific and Efficient Protein Depletion

Here, we present a protocol to effectively and specifically deplete a protein of interest in the yeast Saccharomyces cerevisiae using the β-est AID...
6.6K
Direct Comparison of Hyperspectral Stimulated Raman Scattering and Coherent Anti-Stokes Raman Scattering Microscopy for Chemical Imaging09:46

Direct Comparison of Hyperspectral Stimulated Raman Scattering and Coherent Anti-Stokes Raman Scattering Microscopy for Chemical Imaging

This paper directly compares the resolution, sensitivity, and imaging contrasts of stimulated Raman scattering (SRS) and coherent anti-Stokes Raman scattering (CARS) integrated into the same microscope platform. The results show that CARS has a better spatial resolution, SRS gives better contrasts and spectral resolution, and both methods have similar sensitivity.
4.7K
Coherent Anti-Stokes Raman Spectroscopy to Visualize Myelinated Neurons in Mouse Brain Tissue03:00

Coherent Anti-Stokes Raman Spectroscopy to Visualize Myelinated Neurons in Mouse Brain Tissue

Source: McCullagh, E. A., et al. Coherent Anti-Stokes Raman Spectroscopy (CARS) Application for Imaging Myelination in Brain Slices. J. Vis. Exp. (2022)The video demonstrates fluorescence and Coherent Anti-Stokes Raman Spectroscopy (CARS) imaging to visualize neuronal architecture in rodent brain tissue. Nissl staining labels cell bodies by binding to ribosomal RNA, while CARS imaging targets lipid-rich myelin through laser-induced signals. Overlaying the fluorescence and CARS images provides a...
351
Differential Imaging of Biological Structures with Doubly-resonant Coherent Anti-stokes Raman Scattering (CARS)12:56

Differential Imaging of Biological Structures with Doubly-resonant Coherent Anti-stokes Raman Scattering (CARS)

A combination of three single wavelength short-pulsed lasers is used to generate coherent anti-Stokes Raman scattering (CARS) and doubly-resonant CARS (DR-CARS). The difference between these signals provides enhanced sensitivity for otherwise difficult to detect coherent Raman signals, enabling imaging of weak Raman...
14.0K