関連する概念動画
Line Loss
280
The different configurations of source-load connections include wye (star) and delta connections. The relationship between line and phase voltages and currents varies depending on the configuration. When the source is supplying power, it is transmitted through the wires to the load, and during this transmission, some power is absorbed by the wires, leading to line loss.
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
280
Reducing Line Loss
184
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
184
Minor Losses in Pipes
1.1K
In pipe systems, minor losses refer to energy losses arising from components such as valves, bends, fittings, expansions, and other features that disrupt the steady flow of fluid. These disturbances cause energy dissipation through turbulence and resistance, which engineers quantify to manage system efficiency effectively.
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow...
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow...
1.1K
Lossless Lines
157
In electrical engineering, a lossless transmission line is characterized by a purely imaginary propagation constant and a resistive characteristic impedance. The ABCD parameters, which describe the relationship between the input and output voltages and currents, indicate an equivalent π circuit with an imaginary series impedance and a shunt admittance. This results in a transmission line that, when the product of the phase constant (beta) and the length of the line is less than pi,...
157
Loss of Tumor Suppressor Gene Functions
4.9K
Tumor suppressor genes are normal genes that can slow down cell division, repair DNA mistakes, or program the cells for apoptosis in case of irreparable damage. Hence, they play an essential role in preventing the proliferation of damaged cells.
When the tumor suppressor genes develop mutations or are lost, cells start growing out of control, leading to cancer. However, a single functional copy of the tumor suppressor gene is enough for the cells to maintain their normal functions and cell...
When the tumor suppressor genes develop mutations or are lost, cells start growing out of control, leading to cancer. However, a single functional copy of the tumor suppressor gene is enough for the cells to maintain their normal functions and cell...
4.9K
Forgetting
104
Forgetting is an intrinsic aspect of human memory, characterized by the gradual loss or inaccessibility of information over time. Hermann Ebbinghaus, a pioneering psychologist, extensively studied this phenomenon and formulated the forgetting curve. This curve illustrates that memory loss occurs rapidly immediately after learning and then decelerates over time. Several mechanisms contribute to forgetting, including encoding failure, storage decay, retrieval failure, and interference.
Encoding...
Encoding...
104
こちらも読む
関連記事
共著者、ジャーナル、引用グラフによってこの研究に関連する記事。
並び替え
Same author
Impaired Cerebral Autoregulation in Pediatric Patients with ECMO: A Retrospective Analysis of ECMO Time Periods and Association with Neurologic Injury.
Neurocritical care·2026
Same author
Multicentre analysis of severe perioperative adverse events in children undergoing surgery who were infected with SARS-CoV-2: a propensity score-adjusted analysis.
British journal of anaesthesia·2024
Same author
Association between preoperative respiratory symptoms and perioperative respiratory adverse events in pediatric patients with positive viral testing.
Journal of clinical anesthesia·2023
Same author
Hypothermia after extracorporeal cardiopulmonary resuscitation not associated with improved neurologic complications or survival in children: An analysis of the ELSO registry.
Resuscitation·2023
Same author
Association Between Disrupted Cerebral Autoregulation and Radiographic Neurologic Injury for Children on Extracorporeal Membrane Oxygenation: A Prospective Pilot Study.
ASAIO journal (American Society for Artificial Internal Organs : 1992)·2023