Jove
Visualize
お問い合わせ
JoVE
x logofacebook logolinkedin logoyoutube logo
JoVEについて
概要リーダーシップブログJoVEヘルプセンター
著者向け
出版プロセス編集委員会範囲と方針査読よくある質問投稿
図書館員向け
推薦の声購読アクセスリソース図書館諮問委員会よくある質問
研究
JoVE JournalMethods CollectionsJoVE Encyclopedia of Experimentsアーカイブ
教育
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab Manual教員リソースセンター教員サイト
利用規約
プライバシーポリシー
ポリシー

関連する概念動画

Archival Research01:40

Archival Research

16.4K
Some researchers gain access to large amounts of data without interacting with a single research participant. Instead, they use existing records to answer various research questions. This type of research approach is known as archival research. Archival research relies on looking at past records or data sets to look for interesting patterns or relationships. For example, a researcher might access the academic records of all individuals who enrolled in college within the past ten years and...
16.4K
Formats for Nursing Documentation01:28

Formats for Nursing Documentation

1.2K
Nursing documentation encompasses various formats designed to capture precise patient data, facilitate communication among healthcare team members, and ensure comprehensive and accurate patient records. Let's explore each of these formats in detail:
Nursing Assessment Form:
• A nursing assessment form is a foundational document that captures detailed patient data from physical assessments and nursing histories.
• It includes patient demographics, medical history,...
1.2K
Planning Nursing Care II01:29

Planning Nursing Care II

2.9K
A nursing care plan can present in two forms: informal and formal. Informal is a care plan for the individual use of the nurse and goals they wish to accomplish during their shift. Informal care plans are not included in the patient chart. A formal nursing care plan is a written or computerized guide that organizes patient care. It is further subdivided into two: standardized and individualized care plans. Standardized care plans are pre-populated care plans for specific patient populations,...
2.9K
Methods of Documentation II: POMR01:26

Methods of Documentation II: POMR

1.1K
The Problem-Oriented Medical Record (POMR) revolutionized medical record-keeping by introducing a systematic approach focusing on the patient's problems rather than merely listing symptoms. Dr. Lawrence Weed's introduction of this method in the 1960s marked a significant advancement in medical documentation. The POMR framework consists of four key components: the database, problem list, plan of care, and progress notes.
1.1K
Sampling Plans01:23

Sampling Plans

261
Sampling is a crucial step in analytical chemistry, allowing researchers to collect representative data from a large population. Common sampling methods include random, judgmental, systematic, stratified, and cluster sampling.
Random sampling is a method where each member of the population has an equal chance of being selected for the sample. It involves selecting individuals randomly, often using random number generators or lottery-type methods. For example, when analyzing the properties of a...
261
Methods of Documentation III: PIE01:21

Methods of Documentation III: PIE

1.5K
Problem-intervention-evaluation (PIE) is a systematic approach to documentation used in healthcare settings for clinical decision-making and patient care planning. It is a structured approach to organizing patient data based on problems, interventions, and evaluations. Here's a breakdown of its key features and considerations:
1.5K

こちらも読む

関連記事

共著者、ジャーナル、引用グラフによってこの研究に関連する記事。

並び替え
Same author

Three-Discipline Collaborative Radiation Therapy (3DCRT) debate: Medical physics should focus less on geometric precision and more on biological outcomes.

Journal of applied clinical medical physics·2026
Same author

Evaluation of a Dynamic Collimation System to Improve IMPT Dose Distributions and Maintain Treatment Efficiency.

Cancers·2026
Same author

Commissioning and validation of the Elekta One GPUMCD algorithm for an Elekta VersaHD linear accelerator.

Journal of applied clinical medical physics·2026
Same author

MR-Guided Radiation Therapy for Prostate and Pancreas Cancer Treatment: A Dosimetric Study Across Two Major MR-Linac Platforms.

Cancers·2025
Same author

Range-compensated pencil beam scanning proton Arc therapy: a feasibility study.

Communications engineering·2025
Same author

Improved Survival and Prognostication in Melanoma Patients With Brain Metastases: An Update of the Melanoma Graded Prognostic Assessment.

Journal of clinical oncology : official journal of the American Society of Clinical Oncology·2025
Same journal

Pulse‑level characterization of low monitor unit deliveries on a modern linear accelerator using a plastic scintillation detector.

Journal of applied clinical medical physics·2026
Same journal

Improving image quality in terbium-161 phantom imaging: Quantitative evaluation of DEW and TEW scatter correction methods.

Journal of applied clinical medical physics·2026
Same journal

Latent density discrepancies in commercial lung-equivalent inserts and their clinical dosimetric impact.

Journal of applied clinical medical physics·2026
Same journal

Explainable machine learning for patient-specific quality assurance in intensity-modulated radiotherapy based on anatomical structures.

Journal of applied clinical medical physics·2026
Same journal

Conditional sparing in FLASH radiotherapy: Conformal dosimetry and ALARA remain essential.

Journal of applied clinical medical physics·2026
Same journal

Dual-scan conformal cone-beam CT for targeted image-quality improvement using dynamic collimation.

Journal of applied clinical medical physics·2026
関連記事をすべて見る

関連する実験動画

Updated: Sep 10, 2025

The Participant-Reported Implementation Update and Score PRIUS: A Novel Method for Capturing Implementation-Related Data Over Time
06:05

The Participant-Reported Implementation Update and Score PRIUS: A Novel Method for Capturing Implementation-Related Data Over Time

Published on: February 19, 2021

1.4K

ピナクルプランの改造とアーカイブに関する枠組みの検証

Samuel D Rusu1, Caiden Atienza1, Blake R Smith1

  • 1Department of Radiation Oncology, University of Iowa, Iowa City, Iowa, USA.

Journal of applied clinical medical physics
|August 21, 2025
PubMed
まとめ
この要約は機械生成です。

Sun Nuclear Gatewayは,ピナックルの治療計画データをDICOM形式に変換し,システムのサポートが終了した後,重要な患者の記録へのアクセスを確保しました. この検証済みの溶液は,継続的な患者ケアのための重要な治療情報を保存します.

キーワード:
プロノウTPS アーカイブTPS ファイルの変換ゲートウェイピナクル

さらに関連する動画

Author Spotlight: Improving Radiation Therapy Access with Radiation Planning Assistant
05:18

Author Spotlight: Improving Radiation Therapy Access with Radiation Planning Assistant

Published on: October 6, 2023

1.5K
Author Spotlight: Workflow for Integrating POCUS Data into EHR for Managing Heart Failure Patients
03:47

Author Spotlight: Workflow for Integrating POCUS Data into EHR for Managing Heart Failure Patients

Published on: July 12, 2024

872

関連する実験動画

Last Updated: Sep 10, 2025

The Participant-Reported Implementation Update and Score PRIUS: A Novel Method for Capturing Implementation-Related Data Over Time
06:05

The Participant-Reported Implementation Update and Score PRIUS: A Novel Method for Capturing Implementation-Related Data Over Time

Published on: February 19, 2021

1.4K
Author Spotlight: Improving Radiation Therapy Access with Radiation Planning Assistant
05:18

Author Spotlight: Improving Radiation Therapy Access with Radiation Planning Assistant

Published on: October 6, 2023

1.5K
Author Spotlight: Workflow for Integrating POCUS Data into EHR for Managing Heart Failure Patients
03:47

Author Spotlight: Workflow for Integrating POCUS Data into EHR for Managing Heart Failure Patients

Published on: July 12, 2024

872

科学分野:

  • 医学物理学
  • 放射線腫瘍学
  • データ管理

背景:

  • ピナクル処理計画システムのサポートは2026年12月31日に終了します.
  • 患者の治療歴のデータへのアクセスは,継続的なケアに不可欠です.
  • Pinnacleデータにアクセスするには,検証された方法が必要です.

研究 の 目的:

  • Pinnacle TARデータをDICOM形式に変換するためのソリューションとしてSun Nuclear Gatewayを検証する.
  • Pinnacleのサポート期間を超えて 患者の治療記録への継続的なアクセスを保証します
  • 複数のピナックルの治療プランを 2万件以上 アーカイブする

主な方法:

  • Sun Nuclear Gatewayを使って PinnacleのTARファイルを DICOMに変換した
  • 画像,構造,および2mmまで再サンプリングされたデータをアーカイブします.
  • 品質チェックと3Dガンマ分析 (1%/1mm) を通じて検証された変換精度.

主要な成果:

  • 8つのPinnacleバージョンのデータを成功裏に変換しアーカイブしました.
  • 平均99.96%の3Dガンマパス率を達成しました
  • 初期調整後に0.5%の低い変換誤差率を観測した.

結論:

  • Sun Nuclear Gatewayは,ピナックルのTARデータをDICOMに変換するための検証済みのソリューションです.
  • これは,重要な過去の処理計画データへのアクセスを容易にする.
  • Pinnacleで治療された患者の治療継続を保証します.