:

Sibo Ma1, Yuichi Asada1, Shigehiro Yamaguchi1,2

  • 1Department of Chemistry, Graduate School of Science and Integrated Research Consortium on Chemical Sciences (IRCCS), Nagoya University, Furo, Chikusa, Nagoya 464-8602, Japan. yamaguchi@chem.nagoya-u.ac.jp.

Chemical communications (Cambridge, England)
|August 29, 2025
PubMed
まとめ

私たちは近赤外線 (NIR) 画像処理のための 新しいチエノ・フォスファ・ロダミン (TPR) 染料を開発しました ミトコンドリア膜ポテンシャルやリゾソーム pHなどの細胞機能を追跡する可能性がある.

関連する概念動画

Confocal Fluorescence Microscopy01:16

Confocal Fluorescence Microscopy

Confocal microscopy is an advanced microscopic technique. The prime advantage of the confocal microscope over other microscopy techniques is its ability to block the out-of-focus light from the illuminated samples using pinholes. It is widely used with fluorescence optics to obtain high-resolution, sharp contrast images. Unlike optical microscopes, confocal microscopes use a focused beam of light laser to scan the entire sample surface at different z-planes. These microscopes are, therefore,...
16.0K
Total Internal Reflection Fluorescence Microscopy01:05

Total Internal Reflection Fluorescence Microscopy

Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
11.0K
Super-resolution Fluorescence Microscopy01:37

Super-resolution Fluorescence Microscopy

Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
12.3K
Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)01:15

Insensitive Nuclei Enhanced by Polarization Transfer (INEPT)

Insensitive Nuclei Enhanced by Polarization Transfer (INEPT) is an advanced Nuclear Magnetic Resonance (NMR) technique specifically designed to detect and enhance the signals of low-abundance nuclei, such as carbon-13 and nitrogen-15, in small molecules. The fundamental principle behind INEPT is the transfer of polarization from a more abundant and highly polarizable nucleus, typically hydrogen-1, to the low-abundance nucleus of interest. This process effectively boosts the NMR signal of the...
1.2K
Three-Dimensional Microscopy in Microbiology01:28

Three-Dimensional Microscopy in Microbiology

Three-dimensional imaging techniques are essential in cell biology, allowing researchers to visualize intricate cellular structures with high resolution. Two prominent methods, Differential Interference Contrast Microscopy (DIC) and Confocal Scanning Laser Microscopy (CSLM), provide distinct advantages for imaging live and thick specimens, respectively.Differential Interference Contrast MicroscopyDIC microscopy enhances contrast in transparent, unstained samples by converting phase...
907