High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis
Published on: December 22, 2015
15.6K
まとめ
VIPA分光計用の新しい2次元分散モデルは、ブリルアンシフト測定の精度を向上させ、高解像度の3Dイメージングを実現します。この方法により、自己校正が可能になり、生体組織エラストグラフィなどのアプリケーションの測定時間が短縮されます。
背景:
- 仮想イメージング位相配列(VIPA)は、ブリルアンシフト抽出を可能にするブリルアン顕微鏡検査に不可欠です。
- 高精度なブリルアンシフト測定は、高度な3Dイメージングアプリケーションにとって不可欠です。
結論:
- 新しい2次元分散モデルは、ブリルアンシフト測定の精度と効率を大幅に向上させます。
- この進歩は、生体組織のためのブリルアン顕微鏡検査技術を使用した3Dエラストグラフィの開発にとって重要です。
関連する概念動画
IR Spectrum Peak Splitting: Symmetric vs Asymmetric Vibrations
1.7K
Identical bonds within a polyatomic group can stretch symmetrically (in-phase) or asymmetrically (out-of-phase). Similar to hydrogen bonding, these vibrations also influence the shape of the IR peak. Generally, asymmetric stretching frequencies are higher than symmetric stretching frequencies. For example, primary amines exhibit two distinct IR peaks between 3300–3500 cm−1 corresponding to the symmetric and asymmetric N-H stretching, while secondary amines exhibit a single...
1.7K
IR Spectrometers
2.2K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
2.2K
Raman Spectroscopy Instrumentation: Overview
993
A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
993
UV–Vis Spectrometers
3.3K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
3.3K
UV–Vis Spectroscopy: Woodward–Fieser Rules
28.0K
UV–Visible absorption spectra of conjugated dienes arise from the lowest energy π → π* transitions. The light-absorbing part of the molecule is called the chromophore, and the substituents directly attached to the chromophore are called auxochromes. A strong correlation exists between the absorption maxima, λmax, and the structure of a conjugated π system. The Woodward–Fieser rules predict the value of λmax for a given structure by adding the...
28.0K
IR Spectroscopy: Molecular Vibration Overview
4.4K
When Infrared (IR) radiation passes through a covalently bonded molecule, the bonds transition from lower to higher vibrational levels. The fundamental vibrational motions that result in infrared absorption can be classified as stretching or bending vibrations.
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
Stretching vibrations are vibrational motions that occur along the bond line, changing the bond length or distance between two bonded atoms. They are further distinguished as symmetric or asymmetric. In symmetric stretching, the...
4.4K