関連する概念動画

Zones of Protection01:16

Zones of Protection

730
In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
730
Line Protection with Impedance Relays01:27

Line Protection with Impedance Relays

411
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
411
Reclosers and Fuses01:26

Reclosers and Fuses

428
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
428
Power System Three-Phase Short Circuits01:21

Power System Three-Phase Short Circuits

495
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
495
Insulation Coordination01:23

Insulation Coordination

537
Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times...
537
Radial System Protection01:23

Radial System Protection

405
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
405

こちらも読む

関連記事

共著者、ジャーナル、引用グラフによってこの研究に関連する記事。

並び替え
Same author

An intelligent protection scheme for DC networks using a machine learning-based multi-agent platform.

Scientific reports·2025
Same author

Development and construction of a portable wind tunnel for investigating wind erosion through the application of photogrammetry techniques.

Scientific reports·2025
関連記事をすべて見る

関連する実験動画

Updated: Jan 8, 2026

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
06:04

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator

Published on: February 14, 2025

974

マイクログリッドにおける保護エージェントに基づくパラメータ影響解析付きフォールト分類スキーム

Saman Esmaeilbeigi1, Hossein Kazemi Karegar2, Abolfazl Najar3

  • 1Department of Electrical Engineering, Shahid Beheshti University, Tehran, Iran. s_esmaeilbeigi@sbu.ac.ir.

Scientific reports
|December 22, 2025
PubMed
まとめ

この研究は、マイクログリッド向けのハイブリッド深層ニューラルネットワーク(DNN)を使用した保護エージェント(PA)ベースの方法を導入しています。この研究では、さまざまなパラメータがFDL精度にどのように影響するかを調査し、マイクログリッド保護戦略の改善に洞察を提供します。

キーワード:
深層ニューラルネットワーク(DNN)フォールト検出および位置特定(FDL)インテリジェント電子デバイス(IED)マイクログリッド過電流保護パラメータ影響保護エージェント(PA)

さらに関連する動画

Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
04:35

Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment

Published on: July 5, 2024

2.3K
Author Spotlight: Enhancement of Salient Object Detection for Smart Grid Applications
03:31

Author Spotlight: Enhancement of Salient Object Detection for Smart Grid Applications

Published on: December 15, 2023

990

関連する実験動画

Last Updated: Jan 8, 2026

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator
06:04

Experimental Investigation of the Hierarchical Control in DC Microgrids Using a Real-time Simulator

Published on: February 14, 2025

974
Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment
04:35

Author Spotlight: Simulation and Analysis of the Temperature Rise of Ring Main Unit Equipment

Published on: July 5, 2024

2.3K
Author Spotlight: Enhancement of Salient Object Detection for Smart Grid Applications
03:31

Author Spotlight: Enhancement of Salient Object Detection for Smart Grid Applications

Published on: December 15, 2023

990