時間分解熱脱離型ミニチュア質量分析計による複雑なマトリックス中の複数冷却剤の迅速かつ同時定量
Guiyun Song1,2,3, Huiwen Ruan2,3, Zhigang Fan2,3,4
1Northeastern University, College of Sciences, Research Center for Analytical Sciences, Department of Chemistry, Box 332, Shenyang, 110819, People's Republic of China. jianhuajrz@mail.neu.edu.cn.
Abstract:
Miniaturized mass spectrometry has emerged as a powerful analytical technique characterized by its portability, rapid analysis capability, and operational simplicity, making it particularly suitable for on-site detection across various fields. However, the accurate quantitative determination of multiple compounds in complex matrices remains challenging due to factors such as competitive ionization and limited ion storage capacity. In this study, a time-resolved thermal desorption continuous atmospheric pressure interface ion trap mass spectrometer (TRTD-CAPI-ITMS) coupled with an acetone-assisted photoionization source was developed for simultaneous detection of multiple cooling agents for ensuring product safety and quality control. To evaluate the performance of the system, time-resolved thermal desorption curves of cooling agent mixtures with varying boiling points and concentrations were systematically investigated. The prominent signals of all the cooling agents could be observed simultaneously at a thermal desorption time of 2.0 seconds. However, a key challenge was identified during simultaneous quantitation: non-linear concentration-dependent signal responses were observed with increasing cooling agent concentrations. Competitive ionization between the target cooling agents was confirmed as the primary cause of this phenomenon. To address this issue, two critical parameter adjustments were implemented: (1) reducing the sample load to decrease the number of competing analyte components in the ionization region, and (2) elevating the concentration of acetone dimer reagent ions to ensure sufficient reagent ions for effective ionization of the target cooling agents. As a result, competitive ionization was eliminated, and good linear calibration curves were obtained for all four cooling agents, with all linear correlation coefficients (R2) exceeding 0.99. Finally, the TRTD-CAPI-ITMS was applied to the quantitative determination of cooling agents in commercial dentifrice samples, with whole detection time less than 4 minutes, demonstrating the potential of TRTD-CAPI-ITMS as a powerful tool for field detection of cooling agents in complex matrices, with broad applicability in quality control and safety assessment across relevant industries.
さらに関連する動画
08:56Detection of Regulated Ergot Alkaloids in Food Matrices by Liquid Chromatography-Trapped Ion Mobility Spectrometry-Time-of-Flight Mass Spectrometry
Published on: November 22, 2024
05:48Analysis of Volatile and Oxidation Sensitive Compounds Using a Cold Inlet System and Electron Impact Mass Spectrometry
Published on: September 5, 2014
関連する概念動画
Tandem Mass Spectrometry
MALDI-TOF Mass Spectrometry
Mass Analyzers: Common Types
Matrix-Assisted Laser Desorption Ionization (MALDI)
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...