荷重支持骨接合術構築物におけるプレート作用長が疲労寿命に及ぼす影響:実験的洞察と検証済み有限要素予測
Dominic Mischler1, Mark Glyde2, Michael Kowaleski3
1AO Research Institute Davos, Davos, Switzerland; Graduate School for Cellular and Biomedical Sciences (GCB), University of Bern, Bern, Switzerland.
Background:
Fatigue failure of osteosynthesis plates in load bearing constructs remains a significant clinical challenge, with plate working length (PWL) influencing stress distribution and implant life span. Despite conflicting evidence on PWL's impact, finite element (FE) models offer potential for predicting fatigue life, yet their application to PWL-specific fatigue in bone-plate constructs is limited.
Methods:
This study investigated the effect of PWL on fatigue life in load bearing constructs using experimental cyclic testing and FE modeling. Synthetic bone models with a 10 mm osteotomy gap were stabilized with 3.5 mm stainless steel locking compression plates, testing short (1 empty hole), medium (3 empty holes), and long (5 empty holes) PWL configurations (N = 6 per group) under sinusoidal loading (260 N peak, 3 Hz). A second sub-study assessed the medium PWL across nine load levels (220-380 N). FE models, validated against experimental force-displacement curves, predicted cycles to failure using Basquin's stress-based criteria. Statistical analyses compared experimental and FE-predicted cycles.
Results:
Shorter PWL significantly increased fatigue life (short: 1.19 × 106 ± 0.28 × 106 cycles; medium: 0.35 × 106 ± 0.07 × 106; long: 0.20 × 106 ± 0.04 × 106; p < 0.003). FE predictions closely matched experimental cycles for medium and long PWL (p > 0.05) but underpredicted for short PWL (p = 0.03), likely due to tied interface assumptions. Most short PWL constructs survived beyond 106 cycles, reaching up to 1.5 million cycles in the very high-cycle fatigue regime without failing, where Basquin's accuracy may decrease. Sub-study 2 showed a strong load-life correlation (R2 = 0.96), with FE predictions achieving high accuracy (CCC = 0.972, REE = 6.3 %).
Conclusion:
Shorter PWL enhances fatigue life in load bearing constructs by reducing plate stress, challenging traditional beliefs favoring longer PWL. FE models effectively predict fatigue life for medium and long PWL, supporting preoperative optimization, but require refinement for short PWL, including frictional contact modeling and alternative fatigue models for very high-cycle fatigue. Validation in physiological conditions is needed to enhance clinical applicability.
さらに関連する動画
06:38Establishment of a Segmental Femoral Critical-size Defect Model in Mice Stabilized by Plate Osteosynthesis
Published on: October 12, 2016
07:37Full-field Strain Measurements for Microstructurally Small Fatigue Crack Propagation Using Digital Image Correlation Method
Published on: January 16, 2019
関連する概念動画
Fatigue
Relation between Poisson's ratio, Modulus of Elasticity and Modulus of Rigidity
Saint-Venant's Principle
Design Consideration
The factor of safety is another key...
Impact Loading
In cases of elastic deformation,...
Bending of Members Made of Several Materials
Hooke's Law determines stress in each material, stating that stress is proportional to strain but varies due to each material's...
