温度依存のメカニズムによる歪みと流れの両方を考慮して,ファンアウトパネルレベルのパッケージのダイスシフト予測
Yu-Chi Sung1, Chih-Ping Hu1, Chun-Chieh Hung1
1Department of Mechanical Engineering, National Cheng Kung University, Tainan, 70101, Taiwan.
Scientific reports
|January 3, 2026
まとめ
No abstract available in PubMed .
関連する概念動画
Temperature Dependent Deformation
343
In a nonhomogeneous rod made up of steel and brass, restrained at both ends and subjected to a temperature change, several steps are involved in calculating the stress and compressive load. Due to the problem's static indeterminacy, one end support is disconnected, allowing the rod to experience the temperature change freely. Next, an unknown force is applied at the free end, triggering deformations in the rod's steel and brass portions. These deformations are then calculated and added...
343
Thermal expansion and Thermal stress: Problem Solving
2.0K
San Francisco's Golden Gate Bridge is exposed to temperatures ranging from -15 °C to 40 °C. At its coldest, the main span of the bridge is 1275 m long. Assuming that the bridge is made entirely of steel, what is the change in its length between these temperatures?
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55...
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in temperature (ΔT) is 55...
2.0K
Frequency-Domain Interpretation of PD Control
327
Proportional-Derivative (PD) controllers are widely used in fan control systems to improve stability and performance. A fan control system can be effectively represented using a Bode plot to illustrate the impact of a PD controller through its transfer function. The Bode plot visually conveys how PD control modifies the fan's response across various frequencies, providing a frequency domain interpretation of the controller's behavior.
The proportional control gain, combined with the...
The proportional control gain, combined with the...
327
Maximum Power Flow and Line Loadability
570
The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
570
General External Flow Characteristics
499
The study of external flow is essential for creating structures and objects that interact efficiently and safely with moving fluids, such as air or water. When a body is immersed in a flowing fluid, it experiences two primary forces: drag, which opposes motion along the flow direction, and lift, which acts perpendicular to the flow. The shape, size, and orientation of the object influence these forces.Streamlined and Blunt Bodies in External FlowObjects in fluid flow are classified as...
499
Fast Decoupled and DC Powerflow
705
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
705