角膜全域波面収差ガイド下トランスPRKと加速架橋を併用した角膜ケラトコナスに対する生体力学的、視覚的、屈折的結果:客観的安定性マーカーの使用
Luis Haro-Morlett1, Samuel Arba-Mosquera2, Angelica Hernandez-Solis1
1Cornea, Instituto de Oftalmologia Fundacion Conde de Valenciana IAP, Mexico City, Mexico.
Purpose:
To evaluate the long-term safety and efficacy of simultaneous total corneal wavefront-guided transepithelial photorefractive keratectomy (TCWG-TransPRK) with accelerated corneal cross-linking (CXL) in mild to moderate keratoconus, incorporating corneal biomechanics as objective markers of structural stability.
Methods:
This prospective, interventional, single-center study included patients with mild to moderate keratoconus. All underwent TCWG-TransPRK (maximum planned stromal ablation: 55 µm) followed by accelerated CXL (30 mW/cm2 for 3 minutes; total fluence: 5.4 J/cm2). Follow-up was conducted at 24 hours, 1 week, and 1, 3, 6, and 12 months. Primary outcomes were safety and efficacy, with stress-strain index version 2 (SSI v2) proposed as a key objective marker of biomechanical stability. Additionally, refractive accuracy, tomography, and epithelial remodeling were evaluated.
Results:
Thirty-eight eyes from 19 patients were analyzed. At 12 months, uncorrected distance visual acuity improved from 0.80 ± 0.36 to -0.03 ± 0.10 logarithm of the minimum angle of resolution (P < .0001), with 87% achieving 20/20 and all 20/40 or better. Corrected distance visual acuity improved (P < .0001), with no Snellen line loss. Refractive accuracy was high (89% within ±1.00 diopter). SSI v2 increased significantly (P < .0001), indicating enhanced intrinsic stiffness. No keratoconus progression was observed. Epithelial thickness increased nasally and temporally, correlating with changes in spherical aberration and vertical trefoil.
Conclusions:
Despite the use of accelerated CXL parameters, TCWG-TransPRK with CXL improved vision and enhanced biomechanical stability, as evidenced by a significant increase in SSI v2. This provides an objective structural marker for monitoring and customizing keratoconus care. These findings support the procedure as a safe and effective option for non-progressive mild to moderate keratoconus.
さらに関連する動画
05:14Comparison of Agreement and Accuracy using Binocular Wavefront Optometer with Autorefractor and Phoropter
Published on: September 16, 2025
05:46Author Spotlight: Advancements in Refractive Surgical Correction for Presbyopia and Exploring Postoperative Visual Acuity
Published on: September 20, 2024