高電圧直流(HVDC)の高精度故障識別における改良型1次元残差ネットワーク診断
Rui Li1, Xiaopeng Zhang1, Wei Hao1
1State Grid Shanxi Electric Power Research Institute, Taiyuan, China.
PloS one
|January 20, 2026
まとめ
本研究では、高電圧直流(HVDC)の故障診断のために、注意機構を組み込んだ1D-ResNetを改良したモデルを提案する。改良モデルは精度99.15%を達成し、電力系統の信頼性を大幅に向上させる。
さらに関連する動画
06:09Author Spotlight: Advancing Hepatic Fibrosis Diagnosis Using Magnetic Resonance Elastography and AI
Published on: July 21, 2023
1.9K
11:44Real-Time DC-dynamic Biasing Method for Switching Time Improvement in Severely Underdamped Fringing-field Electrostatic MEMS Actuators
Published on: August 15, 2014
10.8K
関連する概念動画
Fault Types
403
When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
For line-to-line faults occurring between phases B and C, the...
403
DC Generator
2.0K
An alternator converts mechanical energy into electrical energy that varies sinusoidally, resulting in AC current. Meanwhile, a DC generator converts mechanical energy into electrical energy, which are DC pulses with the same polarity. The construction of a DC generator is similar to that of an alternator, except that the pair of slip rings is replaced by a single split ring, also called a commutator. The commutator functions like a periodic rotary switch; it changes the contacts with the...
2.0K
Residual Stresses
599
Residual stresses reside in a structure even after removing the original stress inducer. This phenomenon often arises from varied plastic deformations across different parts of a structure. Consider a rod stretched beyond its yield point. It will not regain its original length due to permanent deformation. Even after load removal, the rod does not entirely lose stress because of uneven plastic deformations, resulting in residual stresses. The computation of these stresses in structures is...
599
Residual Plots
6.2K
A residual plot is a statistical representation of data used to analyze correlation and regression results. It helps verify the requirements for drawing specific conclusions about correlation and regression. To obtain the residual plot, first, the residual for each data value is calculated, which is simply the vertical distance between the observed and the predicted value obtained from the regression equation.
When the residual values are plotted against the variable x, it is called a residual...
When the residual values are plotted against the variable x, it is called a residual...
6.2K
Network Covalent Solids
16.1K
Network covalent solids contain a three-dimensional network of covalently bonded atoms as found in the crystal structures of nonmetals like diamond, graphite, silicon, and some covalent compounds, such as silicon dioxide (sand) and silicon carbide (carborundum, the abrasive on sandpaper). Many minerals have networks of covalent bonds.
To break or to melt a covalent network solid, covalent bonds must be broken. Because covalent bonds are relatively strong, covalent network solids are typically...
To break or to melt a covalent network solid, covalent bonds must be broken. Because covalent bonds are relatively strong, covalent network solids are typically...
16.1K
DC Battery
1.2K
A conductor needs to be a component of a path that creates a closed loop or full circuit to have a continuous current flowing through it. A current starts to flow if an electric field is created inside an isolated conductor that is not part of a full circuit. The conductor quickly develops a net positive charge at one end and a net negative charge at the other. These charges generate an electric field opposite the direction of the applied electric field, which reduces the current. Eventually,...
1.2K