厚い最大強度投影脳コンピュータ断層撮影血管造影によるベースライン側副血行路状態の評価は、術者間の一致を改善する
Mohamed A Al-Shamrani1, Hussain Bin Amir1, Fawaz F Alotaibi1
1Neuroscience Center King Faisal Specialist Hospital and Research Center Riyadh Saudi Arabia.
Background:
In acute ischemic stroke caused by large-vessel occlusion, tissue viability is dependent on the blood supply from leptomeningeal collaterals until reperfusion is achieved. Rapid and accurate evaluation of baseline collateral status is a key marker of eligibility for endovascular therapy but can be challenging to interpret using source images of the computed tomography angiography (SI-CTA). Our objective was to assess whether the use of thick maximum-intensity projection computed tomography angiography (MIP-CTA) improves interrater agreement for evaluation of baseline collaterals status between stroke trainees and an expert stroke neurologist.
Methods:
An expert stroke neurologist and 2 stroke trainees independently reviewed images from 40 brain CTA scans with anterior circulation large-vessel occlusion and assessed collateral status using the Tan collateral scoring system using SI-CTA in the first reading and then using MIP-CTA in the second reading. We calculated interrater agreement and recorded the total time needed in each reading.
Results:
Interrater agreement was fair between the 2 stroke fellows and stroke expert when using SI-CTA (κ=0.45 with 52.5% agreement). After using MIP-CTA, interrater agreement improved to moderate (κ=0.69 with 70% agreement). The median reading time was 1.89 minutes per scan using SI-CTA and 1.00 minute per scan using MIP-CTA (P<0.0001).
Conclusions:
We show that using MIP-CTA, when compared with SI-CTA, shortens interpretation time and improves interrater agreement between stroke trainees and a stroke imaging expert for the evaluation of baseline collaterals in patients presenting with anterior circulation large-vessel occlusion.
関連する概念動画
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies III: Computed Tomography
Maximum Deflection
The maximum deflection occurs at a specific point, known as point O, where the tangent to the deflection curve is horizontal. To find point O, the slope of the tangent at any...
Maximum Power Transfer
By substituting the entire circuit with...
Maximum Size of Aggregate
Fischer Projections


