3D Phase Contrast Using Balanced Steady-State Free Precession (PC-SSFP) for Improved 4D Flow at Clinical Field
Jie Xiang1, Maolin Qiu2, Gigi Galiana1,2
1Department of Biomedical Engineering, Yale University, New Haven, Connecticut, USA.
Magnetic resonance in medicine
|January 27, 2026
まとめ
This study developed a 4D flow balanced steady state free precession (bSSFP) MRI method for improved cardiovascular imaging. The new technique enhances signal-to-noise ratio and contrast, accurately measuring blood flow during diastole.
関連する概念動画
Steady Flow of a Fluid Stream
742
Consider a control volume, such as a pipe with solid boundaries, through which fluid flows and changes direction due to the impulse exerted by the resulting force from the pipe walls. In steady flow, the mass of fluid entering the control volume at a given time, t, with velocity v1, is equal to the mass leaving after infinitesimal time dt, with velocity v2.
During this process, the momentum of the fluid within the control volume remains constant over the time interval dt. By applying the...
During this process, the momentum of the fluid within the control volume remains constant over the time interval dt. By applying the...
742
Phase Contrast and Differential Interference Contrast Microscopy
13.2K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
13.2K
Velocity and Acceleration in Steady and Unsteady Flow
405
In fluid mechanics, velocity and acceleration are key concepts for analyzing particle motion in both steady and unsteady flow. Consider a fluid particle moving along a pathline, where its velocity depends on its position and time. The particle's acceleration is obtained by differentiating the velocity with respect to time.
The acceleration can be generalized to any point in the flow, and expressed as components along three perpendicular directions, representing changes in velocity over...
The acceleration can be generalized to any point in the flow, and expressed as components along three perpendicular directions, representing changes in velocity over...
405
Gyroscope: Precession
5.4K
Precession can be demonstrated effectively through a spinning top. If a spinning top is placed on a flat surface near the surface of the Earth at a vertical angle and is not spinning, it will fall over due to the force of gravity producing a torque acting on its center of mass. However, if the top is spinning on its axis, it precesses about the vertical direction, rather than topple over due to this torque. Precessional motion is a combination of a steady circular motion of the axis and the...
5.4K
Steady, Laminar Flow Between Parallel Plates
847
Understanding steady, laminar flow between parallel plates is essential for analyzing and designing flow in narrow rectangular channels, commonly found in various water conveyance and drainage systems. The Navier-Stokes equations govern fluid motion and are generally challenging to solve due to their nonlinearity. However, simplifications are possible in certain cases, like the steady laminar flow between parallel plates. For this scenario, we assume steady, incompressible, laminar flow.
847
Steady, Laminar Flow in Circular Tubes
1.1K
Hagen-Poiseuille flow describes a viscous fluid's steady, incompressible flow through a cylindrical tube with a constant radius R. This flow profile is often applied to understand fluid transport in narrow channels, such as capillaries. It serves as a foundational example of laminar flow. In this model, cylindrical coordinates (r,θ,z) are used to describe the radial (r), angular (θ), and axial (z) dimensions within the tube. For Hagen-Poiseuille flow, the velocity profile is purely axial,...
1.1K