CO2とH2Oを単原子触媒の電気触媒・熱触媒リレーを通じて分析グレードのプロパナルにアップグレードする
Shifu Wang1,2, Jian Gu3, Xiaobo Yang1
1State Key Laboratory of Catalysis, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, China.
Journal of the American Chemical Society
|January 27, 2026
まとめ
No abstract available in PubMed .
さらに関連する動画
10:57Synthesis and Performance Characterizations of Transition Metal Single Atom Catalyst for Electrochemical CO2 Reduction
Published on: April 10, 2018
19.1K
09:37Imine Metathesis by Silica-Supported Catalysts Using the Methodology of Surface Organometallic Chemistry
Published on: October 18, 2019
10.1K
関連する概念動画
Catalysis
30.4K
The presence of a catalyst affects the rate of a chemical reaction. A catalyst is a substance that can increase the reaction rate without being consumed during the process. A basic comprehension of a catalysts’ role during chemical reactions can be understood from the concept of reaction mechanisms and energy diagrams.
30.4K
Directional Relays
612
Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
612
Conformations of Ethane and Propane
17.1K
In an organic molecule, free rotation about the carbon-carbon single bond results in energetically different conformers of the molecule. Due to this rotation, called the internal rotation, ethane has two major conformations — staggered and eclipsed.
Staggered conformation is a low energy and more stable conformation with the C-H bonds on the front carbon placed at 60°dihedral angles relative to the C-H bonds on the back carbon, leading to a reduced torsional strain. In staggered...
Staggered conformation is a low energy and more stable conformation with the C-H bonds on the front carbon placed at 60°dihedral angles relative to the C-H bonds on the back carbon, leading to a reduced torsional strain. In staggered...
17.1K
Overcurrent Relays
533
Overcurrent relays, crucial for circuit protection, are connected to the secondary current of a current transformer. There are two primary types of overcurrent relays: instantaneous and time-delay.
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
533
Differential Relays
763
Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
763
Line Protection with Impedance Relays
446
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...