ロバストな大腸内視鏡ポリープセグメンテーションのための、マルチスケールおよび不確実性認識アダプテーションを備えた動的Nu T-Loss
Alireza Norouziazad1,2, Mahan Najafpour Ghazvini Fardshad1, Fatemeh Esmaeildoost1,3
1Laboratory of Advanced Biotechnologies for Health Assessments (LAB-HA), Lassonde School of Engineering, York University, Toronto, ON, Canada.
Abstract:
Accurate segmentation of polyps in colonoscopy images is essential for early colorectal cancer detection; however, it remains a challenging task due to reflections, occlusions, motion artifacts, inter- and intra-polyp appearance variability, and the presence of noisy or inconsistent ground-truth annotations. In this work, we introduce dynamic-Nu T-Loss (DNA-TLoss), a robust, adaptive loss function based on the heavy-tailed Student's 𝑡-distribution that incorporates three novel extensions: (1) a per-image learnable degrees-of-freedom parameter ν, predicted by a lightweight NuPredictor network to dynamically adjust robustness to outliers; (2) per-pixel precision weights λ for spatially adaptive error sensitivity; and (3) a multi-scale aggregation scheme that computes and combines loss at multiple spatial resolutions to capture both coarse and fine details. Integrated into a U-Net with a ResNet-34 encoder, DNA-TLoss was evaluated on five public benchmarks: CVC-300, CVC-ClinicDB, ETIS-LaribPolypDB, Kvasir, and CVC-ColonDB. Our method achieves the lowest Hausdorff distance across all datasets, with an average reduction of 14.6% compared to T-Loss; notably, on CVC-300, it yields a significant decrease of 45.96%. It also obtains the lowest false discovery rate on all five datasets, improving over T-Loss by up to 38.7% on CVC-300 and 24.5% on Kvasir. Furthermore, DNA-TLoss provided best-in-class calibration, achieving expected calibration error as low as 0.44% on CVC-300 and outperforming all other baselines on four out of five datasets. These results highlight the promise of joint global and local uncertainty adaptation, coupled with multi-scale optimization, for advancing trustworthy, real-time computer-aided polyp detection in colonoscopy.
さらに関連する動画
06:28E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
06:40A Robust Method for the Large-Scale Production of Spheroids for High-Content Screening and Analysis Applications
Published on: December 28, 2021
関連する概念動画
Adaptations that Reduce Water Loss
The Uncertainty Principle
Self-Awareness and Its Effects
Uncertainty in Measurement: Reading Instruments
Altered States of Awareness
The ingestion of substances like stimulants or hallucinogens leads to chemical alterations in the brain...
Subconsciousness and No Awareness
An illustrative example of subconscious processing is its role in problem-solving. Often, individuals...
