メブロフェニン肝機能指標の正常範囲の確認
Kathy P Willowson1,2, Geoff Schembri1, Elizabeth A Bailey1
1Department of Nuclear Medicine, Royal North Shore Hospital, Sydney, Australia.
Objectives:
To establish normal ranges for [99mTc] Tc-Mebrofenin hepatobiliary scintigraphy (HBS) indices of liver function and the associated uncertainty in clinical measures due to region placement.
Methods:
47 patients referred for gallbladder assessment with no history of liver disease were included in the study. Patients underwent dynamic HBS following injection of 200 MBq of [99mTc] Tc-Mebrofenin at 10 seconds/frame for 36 frames. Analysis was performed by 5 experienced technologists using in-house software (MIM Software, Cleveland, Ohio) to establish blood pool (BP) clearance rate (%/min), blood clearance half-time (min), mebrofenin liver uptake rate (MUR) (%/min) and MUR normalised to body-surface-area (MURBSA) (%/min/m2). Limits of normal ranges (95%) were established and correlation of functional indices with age was investigated. Analysis was repeated after a minimum of 4 weeks to establish intra-user variability and uncertainty associated with measures.
Results:
Data were collected for 27 women and 20 men, with an age range of 20 - 81 years. Twenty-seven patients were aged over 50 and 20 patients were aged below 50. The data were found to have a normal distribution. The mean values derived for the entire cohort for BP clearance rate, blood clearance half time, MUR, and MURBSA were 16.8±2.6 %/min, 4.3±0.7 min, 14.4±2.0 %/min and 8.0±1.5 %/min/m2, respectively. No significant difference in values was found between age groups and no correlation between liver function and age was found. The lower range of normal for MURBSA was established as 5.1%/min/m2, with clinical measures expected to have an uncertainty of ±0. 6 %/min/m2.
Conclusion:
The MURBSA value for a patient with normal liver function can be expected to be approximately 8.0±1.5 %/min/m2, with a lower limit of normal function at 5.1 %/min/m2. Patients receiving liver surgery or treatment that express MURBSA values below this may be at higher risk and should potentially be treated with caution.
さらに関連する動画
関連する概念動画
Variation: Normal Distribution, Range, and Standard Deviation
Indicators
Confirmation Biases
Range
15.9; 16.1; 15.2; 14.8; 15.8; 15.9; 16.0; 15.5
Measurements of the amount of soda in a 16-ounce can vary since different subjects record these measurements or since the exact amount - 16 ounces of liquid, was not...
Normal Distribution
Normal Stress
When a rod is under axial loading, the internal forces and corresponding stress are normal to the plane of the section, so it is termed normal stress. It's important to...