側壁電極アレイを用いた人工内耳植込み後の縦断的音響閾値および同時発生的電極インピーダンスの変化
Meggan J Lind1,2, Camille C Dunn1, Alexander D Claussen1
1Department of Otolaryngology, University of Iowa Hospitals and Clinics, Iowa City Iowa.
Purpose:
To investigate changes in hearing sensitivity post cochlear implantation with MED-EL and Advanced Bionics (AB) lateral wall electrode arrays, with a focus on characterizing delayed onset hearing loss (doHL) and concurrent electrode impedance changes.
Methods:
A retrospective review of 96 adult cochlear implant (CI) recipients (101 ears; MED-EL: 51, AB: 50). Hearing sensitivity was assessed using the low-frequency pure tone average (LFPTA; 125, 250, 500 Hz). Immediate decrements in hearing sensitivity were considered separately from delayed decrements. The incidence, degree, and timing of doHL were characterized. Electrode impedances were considered for individuals with doHL compared with those with stable hearing.
Results:
Median immediate hearing loss was 19 dB across manufacturers. At initial activation, 73% of subjects had functional (LFPTA <80 dB HL) hearing. When all subjects with variable postoperative time periods were included, the incidence of doHL was 27% with a median degree of 24 dB. The median time doHL occurred was 76 weeks. Most (79%) subjects were categorized with gradual decrements rather than precipitous. No MED-EL subjects with doHL experienced concurrent impedance changes; 3 AB subjects did. Incidence of doHL rose to 31% and 44% when considering the subset of subjects with at least 1 year and 2 years of postoperative follow-up, respectively.
Conclusion:
DoHL that was precipitous in nature was observed less frequently than previously reported. Although precipitous hearing loss tended to occur shortly after surgery, most instances of doHL occurred later than anticipated. The absence of concurrent impedance changes for recipients of MED-EL electrode arrays is consistent with previous reports.
関連する概念動画
Standard Electrode Potentials
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
Potentiometry: Types of Electrodes
The Standard Hydrogen Electrode (SHE) is a widely used reference electrode that maintains zero potential across all temperatures. However, its need for a continuous hydrogen gas supply renders it impractical for everyday use.
An alternative to SHE is the Saturated Calomel Electrode (SCE). This electrode features an...
Potentiometry: Membrane Electrodes
Longitudinal Research
Longitudinal Studies