脱細胞化腱ベースの僧帽弁形成輪による変性僧帽弁逆流モデルにおける逆流抑制効果:in vitro拍動流循環試験
Ikuo Katayama1, Shinya Imai1,2, Yusei Okamoto3
1Cooperative Major in Advanced Biomedical Sciences, Joint Graduate School of Tokyo Women's Medical University and Waseda University, Waseda University, Tokyo, Japan.
Objectives:
Conventional annuloplasty rings used in mitral valve repair (MVr) are made of metal or synthetic polymers, which may increase infection risk. This study aimed to develop a mitral annuloplasty ring using decellularised tissue and evaluate its ability to suppress regurgitation in a degenerative mitral regurgitation (DMR) model.
Methods:
A 4 mm diameter annuloplasty ring was created using decellularized bovine tendon. Porcine mitral valve complexes (including the annulus, leaflets, chordae tendineae, and papillary muscles) were obtained from a slaughterhouse. The annulus was enlarged by 4 mm, and the two chordae tendineae of the posterior leaflet (P2) were severed. The DMR model, integrated into a pulsatile flow simulator, was repaired using a commercial-Physio II, Colvin-Galloway (CG) Future, Tailor band, and a decellularised tendon-based ring. Regurgitation control and effective mitral valve area (MVA) were compared (n = 6 for each group).
Results:
The regurgitation rate of the DMR model was 52.3 ± 3.4%, consistent with severe MR. Post-MVr with each ring, the regurgitation rates were 14.9 ± 3.1% (Physio II), 14.5 ± 1.1% (CG Future), 16.4 ± 1.7% (Tailor band), and 15.5 ± 3.0% (decellularised tendon-based biological ring). All of these rates were significantly reduced, with no significant differences among them. Effective MVA was comparable across groups: 2.46 ± 0.28 cm2 (Physio II), 2.33 ± 0.54 cm2 (CG Future), 2.28 ± 0.12 cm2 (Tailor band), and 2.27 ± 0.53 cm2 (decellularised tendon-based biological ring).
Conclusions:
The decellularised tendon-based annuloplasty ring demonstrated functional performance comparable to that of current mitral annuloplasty devices.
さらに関連する動画
11:50High-frequency High-resolution Echocardiography: First Evidence on Non-invasive Repeated Measure of Myocardial Strain, Contractility, and Mitral Regurgitation in the Ischemia-reperfused Murine Heart
Published on: July 9, 2010
11:16In vitro Assessment of Aortic Regurgitation Using Four-Dimensional Flow Magnetic Resonance Imaging
Published on: February 25, 2022
関連する概念動画
Mitral Regurgitation I: Introduction
Mitral Regurgitation III: Medical Management
Mitral Regurgitation IV: Nursing Management
Mitral Regurgitation II: Clinical Features and Diagnostic Tests
Aortic Regurgitation I: Introduction
Mitral Stenosis I: Introduction
