前立腺がんに対するPd-103低線量率組織内照射におけるMRI誘導を用いた線量減少の線量測定学的研究
Andrew Xue1, Lin Wang1, Meredith Akerman2
1Department of Radiation Medicine, Zucker School of Medicine, Northwell Health, Lake Success, New York, NY.
Objectives:
Despite the prevalence of prostate malignancies, there remains a need to improve toxicity profiles while maintaining oncologic control. Standard whole-gland treatment prescriptions have been associated with rectal, bladder, and urethral toxicity. This dosimetric study evaluated a differential dosing approach using Pd-103 low-dose-rate brachytherapy that delivers full prescription dose (125 Gy) to MRI-visible lesions while reducing dose to uninvolved prostate tissue (100 Gy).
Methods:
Twenty-seven patients with unifocal, MRI-visible, biopsy-proven low- or intermediate-risk prostate cancer were identified. For each patient, two dosimetric plans were generated: a standard plan prescribing 125 Gy to the entire prostate, and a de-escalation plan prescribing 125 Gy to the MRI-visible lesion and 100 Gy to the remaining prostate. Dosimetric parameters including rectal D0.1cc and D2cc, bladder D2cc and D10cc, and urethral D10% and D30% were compared using Wilcoxon signed-rank tests.
Results:
Fifty-four plans (27 standard, 27 de-escalation) were analyzed. The de-escalation approach achieved statistically significant dose reductions to all organs at risk (p < 0.0001). Median reductions were: rectum D0.1cc -10.77 Gy (17.7%), D2cc -5.99 Gy (17.4%); bladder D2cc -13.84 Gy (20.1%), D10cc -5.88 Gy (17.4%); and urethra D10% -35.47 Gy (22.5%), D30% -30.14 Gy (21.9%). Large effect sizes were observed for urethral doses (Cohen's d = 1.52-2.01).
Conclusion:
MRI-guided differential dosing in Pd-103 LDR brachytherapy is technically feasible and achieves substantial reductions in organ-at-risk exposure, particularly urethral doses (>20%). While these dosimetric improvements suggest potential for reduced toxicity, clinical validation through our ongoing prospective Phase II trial is needed to confirm clinical benefit.
関連する概念動画
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
Dose Size and Dosing Frequency: Determination Methods
Determination of Multiple Dosing Parameters: Loading and Maintenance Doses
Rational Dosage Regimen: Maintenance Dose and Loading Dose
In most cases, drugs are administered repetitively or infused continuously to maintain a steady-state concentration in the body. At a steady...
Bioavailability Study Design: Single Versus Multiple Dose Studies
Dose-Response Relationship: Overview