HPMCマトリックス錠の非破壊的溶出予測のためのアニー支援UVイメージング
Orsolya Péterfi1, Lilla Alexandra Mészáros1, Bence Szabó-Szőcs1
1Department of Organic Chemistry and Technology, Faculty of Chemical Technology and Biotechnology, Budapest University of Technology and Economics, Műegyetem Rkp. 3., H-1111 Budapest, Hungary.
International journal of pharmaceutics
|February 7, 2026
まとめ
人工ニューラルネットワーク(ANN)と組み合わせたUVイメージングは、ヒドロキシプロピルセルロース(HPMC)含有量を分析することにより、徐放錠からの薬物溶出を正確に予測します。この非破壊的方法は、製剤変更の迅速な評価を提供します。
関連する概念動画
Matrix-Assisted Laser Desorption Ionization (MALDI)
1.2K
Matrix-assisted laser desorption ionization (MALDI) is a powerful analytical technique used in mass spectrometry. It enables the identification and characterization of various biomolecules, including proteins, peptides, nucleic acids, and carbohydrates. MALDI is an ionization technique, widely employed in biological and medical research, as well as in fields like pharmacology and biochemistry.The analyte of interest, a biomolecule or a mixture of biomolecules, is mixed with a suitable matrix...
1.2K
Non-destructive Tests for Concrete Strength
558
The rebound hammer test, also known as the Schmidt hammer test, is a non-destructive technique for evaluating the hardness of concrete and, indirectly, the strength of concrete. It operates on the principle that the rebound of a spring-driven mass from a concrete surface correlates to the surface's hardness. The device comprises a mass within a tubular housing, a spring mechanism, and a plunger that strikes the concrete. Upon release, the energy imparted to the mass by the spring causes it...
558
Predicting Molecular Geometry
46.0K
VSEPR Theory for Determination of Electron Pair Geometries
46.0K
The Extracellular Matrix
89.3K
Overview
89.3K
Prediction Intervals
3.4K
The interval estimate of any variable is known as the prediction interval. It helps decide if a point estimate is dependable.
However, the point estimate is most likely not the exact value of the population parameter, but close to it. After calculating point estimates, we construct interval estimates, called confidence intervals or prediction intervals. This prediction interval comprises a range of values unlike the point estimate and is a better predictor of the observed sample value, y.
However, the point estimate is most likely not the exact value of the population parameter, but close to it. After calculating point estimates, we construct interval estimates, called confidence intervals or prediction intervals. This prediction interval comprises a range of values unlike the point estimate and is a better predictor of the observed sample value, y.
3.4K
UV–Vis Spectrum
2.2K
When light passes through a substance, a portion of the light is absorbed while the remaining light is reflected or transmitted. If the molecule absorbs light between the wavelengths of 180–400 nm range, the UV spectrum is obtained, and if it absorbs light in the 400–780 nm wavelength range, the visible spectrum is obtained.
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar...
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar...
2.2K